toner
61-9417-32 Gas Detector Tube PYROTEC Tube with Calibration Certificate (With Certificate Of Test) 51L
Product Description
Product Model: 61-9417-32Product Brand: GASTEC Corporat […]
Contact Us
Product Details
Product Model: 61-9417-32
Product Brand: GASTEC Corporation
Features
- * Please let us know the address on the certificate.
Spec
- Detecting tube name: 51L Pyrotube
- Number of measurements of 1 box: 5
- Expiration date (year): 3
- Measurement gas name: Dichloromethane
- Measurement range: 1 - 54ppm
- Standard suction times (n): 2
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only, Anesthetic gas
- Measurement gas name: Freon11 (trichlorofluoromethane)
- Measurement range: 0.8 - 43.2ppm
- Standard suction times (n): 2
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon112 (tetrachlorodifluoroethane)
- Measurement range: 1 - 54ppm
- Standard suction times (n): 2
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon113 (trichlorotrifluoroethane)
- Measurement range: 1 - 54ppm
- Standard suction times (n): 2
- Measurement time (hr): -
- Special remarks: Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon113a (trichlorotrifluoroethane)
- Measurement range: 0.8 - 43.2ppm
- Standard suction times (n): 2
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon114 (dichlorotetrafluoroethane)
- Measurement range: 1.8 - 97.2ppm
- Standard suction times (n): 2
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon12 (dichlorotetrafluoroethane)
- Measurement range: 1.8 - 97.2ppm
- Standard suction times (n): 2
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon123 (2,2-Dichloro-1,1,1-trifluoroethane)
- Measurement range: 1.4 - 28ppm
- Standard suction times (n): 2
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon141b (1,1-Dichloro-1-fluoroethane)
- Measurement range: 1.1 - 22ppm
- Standard suction times (n): 2
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon22 (chlorodifluoromethane)
- Measurement range: 2.5 - 135ppm
- Standard suction times (n): 2
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon225 (freon225Ca + freon225Cb 1: equivalent to 1)
- Measurement range: 1.4 - 28ppm
- Standard suction times (n): 2
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Methyl chloride
- Measurement range: 1.6 - 86.4ppm
- Standard suction times (n): 2
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Enflurane
- Measurement range: 25 - 145ppm
- Standard suction times (n): 2
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Halothane
- Measurement range: 3 - 60ppm
- Standard suction times (n): 2
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only
Related product recommendations
You may also be interested in the following products
1-3538-01 [Discontinued]Portable pH Meter HI 9811-5N (Blue) HI9811-5N
model: 1-3538-01
brand: Hanna Instruments
64-7270-83 Pressure Gauge with Glycerin Pressure Range (MPa): 0.0~7.00 GV42-133-7.0MP
model: 64-7270-83
brand: NAGANO KEIKI Co., Ltd.