61-9417-27 Gas Detector Tube PYROTEC Tube with Calibration Certificate (With Certificate Of Test) 51
toner

61-9417-27 Gas Detector Tube PYROTEC Tube with Calibration Certificate (With Certificate Of Test) 51

model: 61-9417-27
brand: GASTEC Corporation
category: toner

Product Description

Product Model: 61-9417-27Product Brand: GASTEC Corporat […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-9417-27
Product Brand: GASTEC Corporation

Features

  • * Please let us know the address on the certificate.

Spec

  • Detecting tube name: 51 Pyrotube
  • Number of measurements of 1 box: 5
  • Expiration date (year): 3
  • Measurement gas name: Freon11 (trichlorofluoromethane)
  • Measurement range: 8 - 320ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
  • Measurement gas name: Freon112 (tetrachlorodifluoroethane)
  • Measurement range: 7 - 280ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
  • Measurement gas name: Freon113 (trichlorotrifluoroethane)
  • Measurement range: 10 - 400ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: N0.840
  • Measurement gas name: Freon113a (trichlorotrifluoroethane)
  • Measurement range: 10 - 400ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
  • Measurement gas name: Freon114 (dichlorotetrafluoroethane)
  • Measurement range: 20 - 800ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
  • Measurement gas name: Freon12 (dichlorotetrafluoroethane)
  • Measurement range: 11 - 440ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
  • Measurement gas name: Freon123 (2,2-Dichloro-1,1,1-trifluoroethane)
  • Measurement range: 14 - 1600ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
  • Measurement gas name: Freon124 (2-chloro-1,1,2,2-tetrafluoroethane)
  • Measurement range: 45 - 1800ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
  • Measurement gas name: Freon141b (1,1-Dichloro-1-fluoroethane)
  • Measurement range: 10 - 1000ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
  • Measurement gas name: Freon22 (chlorodifluoromethane)
  • Measurement range: 25 - 1000ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
  • Measurement gas name: Freon225 (freon225Ca + freon225Cb 1: equivalent to 1)
  • Measurement range: 20 - 800ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
  • Measurement gas name: Methyl chloride
  • Measurement range: 12 - 480ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
  • Measurement gas name: Enflurane
  • Measurement range: 12 - 480ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
  • Measurement gas name: Halothane
  • Measurement range: 240 - 960ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only