Spec

  • Detecting tube name: 103 Lower hydrocarbon
  • Number of measurements of 1 box: 9
  • Expiration date (year): 2
  • Measurement gas name: Acetylene
  • Measurement range: 0.075 - 3.6%
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: Isobutane
  • Measurement range: 0.035 - 1.68%
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: Isopentane
  • Measurement range: 0.045 - 2.16%
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: Ethylene
  • Measurement range: 0.35 - 16.8%
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: Butane
  • Measurement range: 0.035 - 1.68%
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: Propane
  • Measurement range: 0.05 - 2.4%
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: Hexane
  • Measurement range: 0.025 - 1.2%
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: Heptane
  • Measurement range: 0.035 - 1.68%
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: Pentane
  • Measurement range: 0.0375 - 1.8%
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: Lower hydrocarbon
  • Measurement range: 0.05 - 2.4%
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: -