61-9410-75 Gas Detector Tube Acetic Acid with Calibration Certificate (With Certificate Of Test) 81
toner

61-9410-75 Gas Detector Tube Acetic Acid with Calibration Certificate (With Certificate Of Test) 81

model: 61-9410-75
brand: GASTEC Corporation
category: toner

Product Description

Product Model: 61-9410-75Product Brand: GASTEC Corporat […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-9410-75
Product Brand: GASTEC Corporation

Features

  • * Please let us know the address on the certificate.
  • The concentration of various gases in the air can be easily measured by direct reading.
  • You can measure by changing the detector tube with a single detector (pump).
  • Beca*** it is directly readable, there is no individual difference and it is accurate.
  • Each stroke (100 ml) takes 30 to 240 seconds to complete the intensity measurement.

Spec

  • Detecting tube name: 81 Acetic acid
  • Number of measurements of 1 box: 10
  • Expiration date (year): 3
  • Measurement gas name: Acrylic Acid (stabilized with MEHQ)
  • Measurement range: 2 - 50ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: Isovaleric Acid
  • Measurement range: 2 - 50ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: Formic acid
  • Measurement range: 5.2 - 130ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: Propionic Acid
  • Measurement range: 3 - 75ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: Methacrylic Acid (stabilized with MEHQ)
  • Measurement range: 1.8 - 45ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: Acetic acid
  • Measurement range: 1 - 100ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: -
  • Measurement gas name: Maleic Anhydride
  • Measurement range: 0.8 - 20ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: Acetic anhydride
  • Measurement range: 0.6 - 15ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d