61-9410-05 Gas Detector Tube 131La Vinyl Chloride with Calibration Certificate (With Certificate Of Test) 131LA
toner

61-9410-05 Gas Detector Tube 131La Vinyl Chloride with Calibration Certificate (With Certificate Of Test) 131LA

model: 61-9410-05
brand: GASTEC Corporation
category: toner

Product Description

Product Model: 61-9410-05Product Brand: GASTEC Corporat […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-9410-05
Product Brand: GASTEC Corporation

Features

  • * Please let us know the address on the certificate.
  • The concentration of various gases in the air can be easily measured by direct reading.
  • You can measure by changing the detector tube with a single detector (pump).
  • Beca*** it is directly readable, there is no individual difference and it is accurate.
  • Each stroke (100 ml) takes 30 to 240 seconds to complete the intensity measurement.

Spec

  • Detecting tube name: 131La Vinyl chloride
  • Number of measurements of 1 box: 5
  • Expiration date (year): 2 (refrigeration required)
  • Measurement gas name: 1,2,4-Trichlorobenzene
  • Measurement range: 0.65 - 13ppm
  • Standard suction times (n): 4
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: 1,2-Dichloropropane
  • Measurement range: 40 - 800ppm
  • Standard suction times (n): 2
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: 1,3-Dichloropropene
  • Measurement range: 0.5 - 10ppm
  • Standard suction times (n): 2
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: 2-Methylallyl chloride
  • Measurement range: 2.8 - 55ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: p-Ethylbenzyl chloride
  • Measurement range: 2.5 - 50ppm
  • Standard suction times (n): 2
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: Ethyl chloroformate
  • Measurement range: 7 - 140ppm
  • Standard suction times (n): 2
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: Methyl chloroformate
  • Measurement range: 58 - 1160ppm
  • Standard suction times (n): 5
  • Measurement time (hr): -
  • Special remarks: Conversion factor ***d
  • Measurement gas name: Vinyl chloride
  • Measurement range: 0.25 - 54ppm
  • Standard suction times (n): 1
  • Measurement time (hr): -
  • Special remarks: -

Related product recommendations