toner
61-9408-98 Gas Detector Tube Amines with Calibration Certificate (With Certificate Of Test) 180
Product Description
Product Model: 61-9408-98Product Brand: GASTEC Corporat […]
Contact Us
Product Details
Product Model: 61-9408-98
Product Brand: GASTEC Corporation
Features
- * Please let us know the address on the certificate.
- The concentration of various gases in the air can be easily measured by direct reading.
- You can measure by changing the detector tube with a single detector (pump).
- Beca*** it is directly readable, there is no individual difference and it is accurate.
- Each stroke (100 ml) takes 30 to 240 seconds to complete the intensity measurement.
Spec
- Detecting tube name: 180. Amines
- Number of measurements of 1 box: 10
- Expiration date (year): 3
- Measurement gas name: N,N-Diethylethanolamine
- Measurement range: 6 - 120ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: N,N-Dimethylethylamine
- Measurement range: 4 - 80ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: N.N-Dimethylethanolamine
- Measurement range: 6.5 - 130ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: N-Ethylmorpholine
- Measurement range: 5 - 100ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: n- Butylamine
- Measurement range: 8 - 160ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: N-Methylmorpholine
- Measurement range: 5 - 100ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: tert-Butylamine
- Measurement range: 5.5 - 110ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Amines
- Measurement range: 5 - 100ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: -
- Measurement gas name: Ammonia
- Measurement range: 1.5 - 30ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Isopropylamine
- Measurement range: 5.5 - 110ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Ethanolamine (monoethanolamine)
- Measurement range: 7 - 140ppm
- Standard suction times (n): 3
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Ethylamine
- Measurement range: 5 - 100ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Ethylenediamine
- Measurement range: 14 - 280ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Di -n- Butylamine
- Measurement range: 5 - 100ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Diisopropylamine
- Measurement range: 5 - 100ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Diethylamine
- Measurement range: 5.5 - 110ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Cyclohexylamine
- Measurement range: 7 - 140ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Dipropylamine
- Measurement range: 4 - 80ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Dimethylaminopropylamine
- Measurement range: 8 - 160ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Dimethylamine
- Measurement range: 5.5 - 110ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Tetramethylenediamine
- Measurement range: 8.5 - 170ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Triethylamine
- Measurement range: 4.5 - 90ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Trimethylamine
- Measurement range: 3.5 - 70ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Propylamine
- Measurement range: 6 - 120ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Hexylamine
- Measurement range: 9 - 180ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Methylamine
- Measurement range: 5 - 100ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Morpholine
- Measurement range: 9 - 180ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Propylenimine
- Measurement range: 5.5 - 110ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: N-methylpyrrolidone
- Measurement range: 13.5 - 270ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d