laboratoryinstruments
61-0163-62 Epp***orf Xplorer ® plus Single channel 4861 000.708
Product Description
Product Model: 61-0163-62Product Brand: Eppendorf AG Fe […]
Contact Us
Product Details
Product Model: 61-0163-62
Product Brand: Eppendorf AG
Features
- The Epp***orf Xplorer is an electric pipette. Single, 8 and 12 channel pipettes were designed to aspirate and dispense liquid volumes from 0.5 μL to 10 mL. In addition, it removes much of the risk of potential manual pipetting errors. Intuitive operating concepts and ergonomic design, supported by the Epp***orf PhysioCare Concept ®, set a new standard for ease, accuracy and reproducibility. You can set it to nine different languages: Chinese, Dutch, English, French, German, Italian, Japanese, Portuguese, and Spanish. The Xplorer pipette is the device of choice when you need precisely adjustable parameters, reproducible and accurate results. This allows fatigue-free pipetting and maintains full control of the pipetting procedure at all times.
- Intuitive work concept for quick and easy work
- Multi-function rocker switch
- Selection dial
- Innovative ejector button
- Ergonomic display angle
- Convenient operation
- Powerful battery
- Flexible charging concept
- Spring-type nose cone (other than 5 mL and 10 mL)
- Adjustable according to external conditions (Geographic elevation, high density liquid, etc.)
Spec
- capacity Range : 0.5 -10 μL
- color codes: gray
- capacity : 0.5 μL
- 0.5 Relative systematic error in μL 1 ) : ± 6.0%
- 0.5 Absolute systematic error on μL 1 ) : ± 0.03 μL
- 0.5 μL Relative Coincidence Error 1 ) : ± 3.0%
- 0.5 μL Absolute Coincidence Error 1 ) : ± 0.015 μL
- capacity : 1 μL
- (a) Relative systematic error in μL 1): ± 2.5%
- 1 Absolute systematic error at μL 1): ± 0.025 μL
- (a) Relative random error in μL 1): ± 1.8%
- 1 μL time Absolute chance error 1): ± 0.018 μL
- capacity : 5 μL
- 5 Relative systematic error in μL 1): ± 1.5%
- 5 Absolute systematic error at μL 1): ± 0.075 μL
- 5 μL Relative Coincidence Error 1): ± 0.8%
- 5 μL Absolute Coincidence Error 1): ± 0.04 μL
- capacity : 10 μL
- 10 Relative systematic error in μL 1 ) : ± 1.0%
- 10 Absolute systematic error on μL 1 ) : ± 0.1 μL
- 10 μL Relative Coincidence Error 1 ) : ± 0.4%
- 10 μL Absolute Coincidence Error 1 ) : ± 0.04 μL
- 1) chisel, EN ISO 8655 error data applies when using genuine Epp***orf chips. Technical specifications are subject to change. Information may be incorrect or missing.
- Electric dispensing Pipette
Related product recommendations
You may also be interested in the following products
61-9659-89 Square Vacuum Constant-Temperature Drying Apparatus DP200
model: 61-9659-89
brand: Yamato Scientific Co., Ltd.
4-5929-01 Stainless Steel Test Sieve φ450 x Depth 100 Mesh Opening 125.0 mm
model: 4-5929-01
brand: NONAKA RIKAKI Co., Ltd.
6-265-01 Auto Burette With Glass Screw Stopcock 10mL 022210-10
model: 6-265-01
brand: SIBATA SCIENTIFIC TECHNOLOGY LTD.