Product Description
Product Model: 61-4483-26Product Brand: KANOMAX JAPAN I […]
Contact Us
Product Details
Product Model: 61-4483-26
Product Brand: KANOMAX JAPAN INCORPORATED
Features
- Handy type that measures CO, CO2, temperature and humidity simultaneously in one unit.
- Dew point, wet bulb temperature, absolute humidity and ventilation rate can be calculated from the measurement items.
- If you need a document, it will cost separately.
Spec
- Measurement target: Clean air flow
- Carbon monoxide (CO) measurement method: Electrochemical formula
- (Measurement range: 0.1 - 500ppm
- (Display resolution: 0.1 - 99.9ppm: 0.1ppm, 100 - 500ppm: 1ppm)
- (Measurement accuracy: The larger value of ±3% of the indicated value and ±3ppm (at 20℃))
- (Responsiveness: Approximately 60 seconds (90% response, When using calibration cap))
- Carbon dioxide (CO2) measurement method: Non dispersive Infrared (NDIR)
- (Measurement range: 0 - 5000ppm)
- (Display resolution: 1ppm)
- (Measurement accuracy: The larger value of ±3% of the indicated value and ±50ppm (at 20℃))
- (Responsiveness: Approximately 45 seconds (90% response, When using calibration cap))
- Temperature measuring method: Platinum resistance thermometer method
- (Measurement range: -20.0 - 60.0℃)
- (Display resolution: 0.1℃)
- (Measurement accuracy: ±0.5℃)
- (Responsiveness: Approximately 60 seconds or less (wind speed 1m/s, 90% response))
- Humidity measuring method: Capacitance type
- (Measurement range: 2.0 - 98.0%RH)
- (Display resolution: 0.1%RH)
- (Measurement accuracy: 2 - 80%RH: ±2.0%RH, 80 - 98%RH: ±3.0%RH)
- (Responsiveness: Approximately 15 seconds (90% response))
- Measurement function: Measurement value hold, Maximum value hold,
- Battery remaining amount display (5 stages), Time display function, Atmospheric pressure correction function, Gas Calibration
- Change for the unit of measurement (Temperature, dew-point temperature, wet-bulb temperature: ℃ or ?
- Absolute temperature: g/m3 or lb/ft3 (Humidity rate: g/kg or lb/lb)
- Maximum, minimum, average value measurement (measurement interval: 1 - 999 seconds, Measurement times: 1 - 999 times, Maximum memory: 1500 data), Ventilation rate measurement
- Output function (digital output): RS-232C (baud rate: 4800, 9600, 19200, 38400bps) (*For output/input to printer, PC)
- Output function (analog output) * DC0 - 1V (CO, CO2, Temperature, Humidity; whichever to 1ch output)
- Power supply: AA Dry cell x 6 pieces (Alkaline cell is available), AC adapter *: 100 - 240VAC (50/60Hz)
- Continuous measurement hour: Approximately 10 hours (Temperature: 20℃, When alkaline cell is ***d, When RS-232C is not ***d)
- Operating temperature environment: Body/5 - 40℃, Probe/- 20 - 60℃ (non condensing for both)
- Storage temperature environment: - 20 - 60℃ (non condensing)
- Weight: Body/Approximately 400g (including cell), Probe/Approximately 250g
- Outer dimensions: Body/Approximately 88 x 188 x 51mm, Probe measurement unit/Approximately φ25 x 169mm, Probe Grip/Approximately φ32 x 151mm
- Accessories: Carrying case x 1 piece, AA dry battery x 6 pieces, Cap and tube for calibration x 1 set, Probe stand x 1 piece, Simplified measurement software (Windows version) x 1 set, RS-232C communication cable x 1 piece, Instruction manual x 1 volume
- Optional product: Preliminary probe, Analog output, Printer, Printer cable, Zero gas, CO span gas, CO2 span gas, Regulator, AC adapter
- *means optional item
Related product recommendations
You may also be interested in the following products
65-4300-66-20 Sealed Pressure Gauge (100Φ) Vertical A Frame with 0.06 MPa Inspection Certificate BE10-183
model: 65-4300-66-20
brand: NAGANO KEIKI Co., Ltd.
65-3534-07 [Out of stock]Temperature Sensor S Series for High Performance Self-Weight Static Surface -50~600°C E Type with ISO Documents S-780E-GW1-ASP
model: 65-3534-07
brand: ANRITSU METER CO., LTD.
63-2914-46 [Discontinued]Digital Thermo-Hygrometer Home A Highest/Lowest White 73030
model: 63-2914-46
brand: Shinwa Rules Co., Ltd.
67-6308-66 Temperature Sensor for Static Surfaces Contact Support Type φ12 Stainless Steel Guard (Standard/Grounding) 90° (Elbow Used) Type K Pipe L: 30 Standard Plug AX-334K-00-1-TC1-ASP
model: 67-6308-66
brand: ANRITSU METER CO., LTD.