Product Description

Product Model: 2-1880-01 Features Simultaneous detectio […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 2-1880-01

Features

  • Simultaneous detection and display of five elements: Na, K, Li, Ca, and Ba.
  • There is no need to replace interference filters.
  • Integrated system with built-in quiet compressor.
  • ppm, mg/l, meq/l, mmol/l, units A flexible calibration unit.
  • Windows (R) environment PC software is provided as standard. Data logging, GLP file storage, and data transfer are easy.
  • It supports propane, butane, LPG and natural gas (optional) and maintains safety by the automatic flame extinguishing function. (CE Safety Standard)
  • City gas compatible kit: As a standard, the main body has a propane gas regulator, so you need to replace the regulator when using city gas.
  • Cassette cylinder regulator: Allows the *** of a ho***hold cassette cylinder (propane gas) if the laboratory does not have a gas connection.

Spec

  • Size (mm): 380 x 410 x 510
  • Weight (kg): 1
  • Optimum measurement range (1 point calibration): Na/0.05 - 60ppm, K/0.05 - 100ppm, Li/0.1 - 50ppm, Ca/2.5 - 100ppm
  • Optimum measurement range (multipoint calibration): Na/0.05 - 1000ppm, K/0.05 - 1000ppm, Li/0.1 - 1000ppm, Ca/2.5 - 1000ppm, Ba/30 - 3000ppm
  • Reproducibility: within 1% (when measuring 20 samples (100ppm or less) for more than 30 minutes)
  • Minimum detection accuracy: Na/0.02ppm, K/0.02ppm, Li/0.05ppm, Ca/1.0ppm, Ba/10ppm
  • Stable time: within 15 seconds (after putting sample into flame)
  • Accessories gas hose, Clamp, PC software, DVD, Nebulizer set (needle, suction tube, cleaning wire), PC interface load, Droplet receiving, Waste tube: F*** x 2, 1mL, 10mL pipette x 10 each, Normal diluted solution, Pure water, Cleaning agent solution, Concentration liquid (sodium, potassium, lithium, calcium, barium)
  • Model number: OSK 55XC750

Related product recommendations

You may also be interested in the following products

61-6974-14 Z Axis Aluminum Stage (Vertical) Size 25 x 25mm TADC-253L
Analyzer, Testing Equipment
62-8507-24 Anti-CBX1 (HP1 beta) Antibody, clone 5E9.1 MABE664
Analyzer, Testing Equipment

62-8507-24 Anti-CBX1 (HP1 beta) Antibody, clone 5E9.1 MABE664

model: 62-8507-24 brand: Sigma Aldrich Japan(Millipore)
65-1747-53 1.5 mL Sc-Vial Transparent Scale 100 pcs 11191205
Analyzer, Testing Equipment

65-1747-53 1.5 mL Sc-Vial Transparent Scale 100 pcs 11191205

model: 65-1747-53 brand: La-Pha-Pack Corporation
61-0376-62 [Discontinued]3-Phenoxybenzoic Acid for Synthesis 841319 5G 8.41319.0005
Analyzer, Testing Equipment