61-6985-03 [Discontinued]Automatic Rotation Stage Φ40mm 19.6N (2.0kgf) SGSP-40YAW
Analyzer, Testing Equipment

61-6985-03 [Discontinued]Automatic Rotation Stage Φ40mm 19.6N (2.0kgf) SGSP-40YAW

model: 61-6985-03
brand: SIGMAKOKI CO., LTD.

Product Description

Product Model: 61-6985-03Product Brand: SIGMAKOKI CO., […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-6985-03
Product Brand: SIGMAKOKI CO., LTD.

Features

  • It is a rotating stage driven by a stepping motor using bearings for the guide and worm gears for the feed mechanism.
  • Automatic stage suitable for positioning for measurement, inspection and evaluation equipment.
  • In the automatic rotation stage, the CW limit sensor is ***d as the origin sensor to return to the origin.
  • The origin detection is adjusted so that it stops at 0 degrees when the origin return operation is performed using the MINI method at half-step.
  • * Caution is required when using the product in reverse direction or on a vertical surface.
  • * Accuracy and load capacity may not meet some specifications dep***ing on the mounting direction.

Spec

  • [

    Common specification]
  • Motor type: 5 phase stepping motor 0.66 A/phase (Tamagawa Seiki (Co., Ltd.))
  • Motor product number: TS3664N4 (□24mm)
  • Motor step angle: 0.72°
  • Sensor power voltage: DC5 - 24V±10%
  • Sensor power consumption: 15mA or less
  • Sensor control output: NPN open collector output DC 30V or less 50mA or less
  • Sensor output logic: When shading > Output transistor OFF (non-conducting)
  • Compatible driver: SG-5M, SG-5MA, SG-55M, SG-55MA, SG-514MSC, SG-5151, KR-525M
  • Compatible controller: PAT-001, GSC-01, SHOT-102, GSC-02, SHOT-702, GIP-101, SHOT-302GS, SHOT-304GS, HIT-M・HIT-S
  • [Individual specification]
  • Rotation range: In counter Clockwise CCW direction, at ∞, In clockwise CW direction near at 0 degree (? 2.5°), it stops
  • Table surface size: φ40mm
  • Transfer mechanism (reduction ratio): Worm gear (1: 144)
  • Movement guide: Bearing system
  • Stage material: Aluminum, aluminum bronze
  • Mass: 0.35kg
  • Resolution (full): 0.005°/Pulse
  • Resolution (half): 0.0025°/Pulse
  • Max speed: 30°/sec
  • Positioning accuracy: 0.1°
  • Repeatable positioning accuracy: 0.02°
  • Withstand load: 19.6N (2.0kgf)
  • Moment stiffness: 2″/N・cm
  • Lost motion: 0.05°
  • Backlash: 0.1°
  • Parallelism: 50μm
  • Concentricity: 30μm
  • Wobble: 0.02mm
  • Sensor product number: Microphoto sensor: PM-F24 (SUNX Co., Ltd.)
  • Limit sensors: Is available (NORMAL CLOSE)
  • Origin sensor: No
  • Proximity origin sensor: No
  • CE conform product
  • RoHS conform product

Related product recommendations

You may also be interested in the following products

62-8487-37 Anti-Epidermal Growth Factor Receptor (Ab-5) Mo*** mAb (EGFR.1) GR15L-100UG
Analyzer, Testing Equipment
61-0256-84 Millistak+(R) Pod F0HC 0.55 M2 Flatseal1P 1ST MF0HC05FS1
Analyzer, Testing Equipment

61-0256-84 Millistak+(R) Pod F0HC 0.55 M2 Flatseal1P 1ST MF0HC05FS1

model: 61-0256-84 brand: Merck Millipore Corporation
61-0369-44 [Discontinued]1-Bromo-4-Chlorobenzene for Synthesis 821969 5G 8.21969.0005
Analyzer, Testing Equipment