![61-0253-43 [Discontinued]Opticap XL10 Viresolve NFR 1.5In. TC/TC 1/Pk 1ST KZRVA10TT1](https://www.jgauge.com/wp-content/uploads/2025/08/6a7e2a9fd96c601a4a2de6c71d5342e6.webp)
Analyzer, Testing Equipment
61-0253-43 [Discontinued]Opticap XL10 Viresolve NFR 1.5In. TC/TC 1/Pk 1ST KZRVA10TT1
Product Description
Product Model: 61-0253-43Product Brand: Merck Millipore […]
Contact Us
Product Details
Product Model: 61-0253-43
Product Brand: Merck Millipore Corporation
Spec
-
Filtration area, m
2
: 0.43 - Hold-up volume, mL: 175
- Processing capacity, L: 600?1200
- Length, cm (inch): 33 (13)
- Support material: Polypropylene
- Seal material: Silicone
- Device material: Polypropylene
- Vent cap material: Polypropylene
- Material: Polyethersulfone
- Application: Retrovirus removal
- Brand name: Viresolve
- Main application: Protein Purification
- Package: Double easy open bag
- Form: Capsule
- Connection, Vent/drain: 1/4in. hose port double O-ring seal
- Connection, Inlet/outlet: 38 mm (1-1/2in.) sanitary flange
- Quantity/box: 1
- Overview: Opticap XL 10 Viresolve NFR 1-1/2in. TC/TC
- Product name: Opticap XL 10 capsule filter
- Maximum Inlet Pressure (psig): 80
- Maximum Inlet Temperature, °C: 25
- Air diffusion flow rate, 23 °C: ?16mL/minute @ 340kPa (50psig), moisted in water
- Maximum input pressure, kPa (psi): 550 (80) @ 23 °C
- Maximum differential pressure, kPa (psid): Forward: 550(80), reverse direction: 340(50)
- Sterilization: After wetting, Liquid cycle, with slow exhaust, Autoclave sterilization at 125℃ for 60 minutes, available up to 3 times
-
Total extract: The extractables level was equal to or less than 35
mg after a 10
minute 1.5
LPM/ft2 flush and 24
hours in water at controlled room temperature. - Potassium permanganate reduced substance: Effluent after flashing with 4L of water conforms to USP Oxidizable Substances Test
- ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.
Related product recommendations
You may also be interested in the following products
61-6430-45 COL-ELITE 200 60m 0.32mm 1.00μm N9316631
model: 61-6430-45
brand: PerkinElmer, Inc.
61-0209-61 [Discontinued]Temperature/Relative Humidity Probe (Ergotouch Pro) 144135 1Pc 1.44135.0001
model: 61-0209-61
brand: Merck Millipore Corporation
61-0341-66 Tetra-N-Butyltin for Synthesis 808278 100mL 8.08278.0100
model: 61-0341-66
brand: Merck Millipore Corporation
61-0331-50 4-Chlorostyrene (Stabilized with TBC) (Stabilizer:4-Tert-Butylpyrocatechol) for Synthesis 802458 10mL 8.02458.0010
model: 61-0331-50
brand: Merck Millipore Corporation