Spec

  • Filtration area, m

    2

    : 2.07
  • Length from inlet to outlet, cm (inch): 17.5 (6.9)
  • Filter bore diameter, μm: 0.1
  • Length, cm (inch): 87.1 (34.3)
  • Length, Inch (cm): 30 (75)
  • Support material: Polyester
  • Seal material: Silicone
  • Device material: Gamma compatible polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Form: Capsule
  • Connection, Inlet/outlet: 38mm (1-1/2in.) sanitary flange/16mm (5/8in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XLT30 Durapore 0.1μm gamma compatible 1-1/2in. TC-5/8in. HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    63.3mL/min at 390kPa (56psig) wetted with water
  • Bubble point, 23 °C:


    483kPa (70psig) water-wet and air
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization at 126℃ for 60 minutes for 3 times; 45 kilogray (4.5 Megarad) gamma irradiation compatible; in-line steam sterilization is unavailable
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 75


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 3L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8362-90 m-ColiBlue24(R) Broth M00PMCB24
Analyzer, Testing Equipment

62-8362-90 m-ColiBlue24(R) Broth M00PMCB24

model: 62-8362-90 brand: Sigma Aldrich Japan(Millipore)
62-8410-03 bpV(bipy) 203694-5MG
Analyzer, Testing Equipment

62-8410-03 bpV(bipy) 203694-5MG

model: 62-8410-03 brand: CBC(Merck)
4-2895-01 Digital microscope camera camera main Main Unit MIC-143C
Analyzer, Testing Equipment
61-0230-22 Clarigard Cart Filt 10In. 1.0μm Code F PE 1/Pk 1ST D010F1P01
Analyzer, Testing Equipment