Analyzer, Testing Equipment
61-0251-67 [Discontinued]Opticap Gamma Compatible Sterilizing Grade XLT30 Durapore 0.1μm 1.5In Tc-5/8In HB 1/Pk 1ST KVVLG3TTH1
Product Description
Product Model: 61-0251-67Product Brand: Merck Millipore […]
Contact Us
Product Details
Product Model: 61-0251-67
Product Brand: Merck Millipore Corporation
Spec
-
Filtration area, m
2
: 2.07 - Length from inlet to outlet, cm (inch): 17.5 (6.9)
- Filter bore diameter, μm: 0.1
- Length, cm (inch): 87.1 (34.3)
- Length, Inch (cm): 30 (75)
- Support material: Polyester
- Seal material: Silicone
- Device material: Gamma compatible polypropylene
- Vent cap material: Polypropylene
- Material: Hydrophilic PVDF
- Housing: Polypropylene
- Filter brand name: Durapore(R)
- Brand name: Opticap
- Main application: Laboratory Filtration
- Form: Capsule
- Connection, Inlet/outlet: 38mm (1-1/2in.) sanitary flange/16mm (5/8in.) hose port
- Quantity/box: 1
- Overview: Opticap XLT30 Durapore 0.1μm gamma compatible 1-1/2in. TC-5/8in. HB
- Product name: Opticap XLT capsule filter
- Maximum Inlet Pressure (psig): 80
- Maximum Inlet Temperature, °C: 25
- T-line/Gauge Port: T-line
-
Air diffusion flow rate, 23 °C:
63.3mL/min at 390kPa (56psig) wetted with water -
Bubble point, 23 °C:
483kPa (70psig) water-wet and air -
Maximum input pressure, kPa (psi): 552 (80) @ 25
°C; 276 (40) @ 60
°C; 103 (15) @ 80
°C - Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
- Wettability: Hydrophilic
- Sterilization: Autoclave sterilization at 126℃ for 60 minutes for 3 times; 45 kilogray (4.5 Megarad) gamma irradiation compatible; in-line steam sterilization is unavailable
- Sterility: No sterilization
-
Total extract: The extractables level was equal to or less than 75
mg per capsule after 24
hours in water at controlled room temperature. - Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 3L
- ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.
Related product recommendations
You may also be interested in the following products
61-0362-51 [Discontinued]Chloride N,N-Diphenyl Hydrazinium for Synthesis 820535 10G 8.20535.0010
model: 61-0362-51
brand: Merck Millipore Corporation
62-8376-89 [Discontinued]Ro 25-6981 Maleate Salt 5.04845.0001
model: 62-8376-89
brand: CBC(Merck)
62-8514-15 Anti-CD161 (NK1.1) (mo***), FITC, clone PK136 Antibody MABF1490
model: 62-8514-15
brand: Sigma Aldrich Japan(Millipore)
61-0226-34 Polygard-CR Cart Filt 20In. 0.5μm Code 7 Silicone 6/Pk 6 x 1ST CRA572006
model: 61-0226-34
brand: Merck Millipore Corporation