61-0251-14 [Discontinued]Opticap Sterilizing Grade XL10 Multimedia 1.2/0.5/0.22μm 3/4In TC/TC 1/Pk 1ST KVSCA10FF1
Analyzer, Testing Equipment

61-0251-14 [Discontinued]Opticap Sterilizing Grade XL10 Multimedia 1.2/0.5/0.22μm 3/4In TC/TC 1/Pk 1ST KVSCA10FF1

model: 61-0251-14
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0251-14Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0251-14
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.56
  • Filter bore diameter, μm: 1.2 / 0.5 / 0.22
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, cm (inch): 33.5 (13.2)
  • Length, Inch (cm): 10 (25)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Pre-filter material: Cellulose mixed ester
  • Vent cap material: Polypropylene
  • Material: Cellulose mixed ester; hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 19mm (3/4in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XL10 multimedia 1.2/0.5/0.22μm 3/4in. TC/TC
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Air diffusion flow rate, 23 °C:


    10.8mL/min @ 280kPa (40 psig) in water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 103 (15) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Highest operating temperature, ℃: 80 °C
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 75


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 5L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-6387-38 Sealed Specimen Bag Basic Set HS-010
Analyzer, Testing Equipment
61-0317-99 Lichrocart(R) 55-4 Purospher STAR RP-18e (3μm) HPLC Cartridge 3 Set 150231 1ST 1.50231.0001
Analyzer, Testing Equipment
65-0579-06 phi 15 reaction vessel set GPS-15G
Analyzer, Testing Equipment

65-0579-06 phi 15 reaction vessel set GPS-15G

model: 65-0579-06 brand: TOKYO RIKAKIKAI CO., LTD.