61-0250-44 [Discontinued]Opticap XLT30 Durapore 0.22μm 1In. HB/HB; 1/Pk 1ST KVGLA3TBB1
Analyzer, Testing Equipment

61-0250-44 [Discontinued]Opticap XLT30 Durapore 0.22μm 1In. HB/HB; 1/Pk 1ST KVGLA3TBB1

model: 61-0250-44
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-44Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-44
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 2.07
  • Filter bore diameter, μm: 0.22
  • Length, cm (inch): 30
  • Length, Inch (cm): 30 (75)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 25mm (1in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XLT30 Durapore 0.22μm 1in. HB/HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    40mL/min @ 280kPa (40 psig) in water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 75


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 3L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0346-67 Methyl Propyl Ketone for Synthesis 814536 2.5L 8.14536.2500
Analyzer, Testing Equipment
61-0381-25 [Discontinued]1,9-Nonanediol for Synthesis 841835 25G 8.41835.0025
Analyzer, Testing Equipment
61-0368-29 3-(Triethoxysilyl) Propylamine for Synthesis 821619 100mL 8.21619.0100
Analyzer, Testing Equipment
64-1071-41 Column pressure resistance 1.96 MPa or Less ILC-C22-150
Analyzer, Testing Equipment