61-0250-37 [Discontinued]Opticap XLT20 Durapore 0.22μm 1In. HB/HB; 1/Pk 1ST KVGLA2TBB1
Analyzer, Testing Equipment

61-0250-37 [Discontinued]Opticap XLT20 Durapore 0.22μm 1In. HB/HB; 1/Pk 1ST KVGLA2TBB1

model: 61-0250-37
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-37Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-37
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 1.38
  • Filter bore diameter, μm: 0.22
  • Length, cm (inch): 20
  • Length, Inch (cm): 20 (50)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 25mm (1in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XLT20 Durapore 0.22μm 1in. HB/HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    26.6mL/min @ 280kPa (40 psig) in water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 50


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 2L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0324-30 4’-Dimethylacetanilide for Synthesis 800077 250G 8.00077.0250
Analyzer, Testing Equipment
68-0953-63 Miniature Polarizing Microscope DSM-IP
Analyzer, Testing Equipment
61-0367-87 4-Methoxyphenol for Synthesis 821233 250G 8.21233.0250
Analyzer, Testing Equipment

61-0367-87 4-Methoxyphenol for Synthesis 821233 250G 8.21233.0250

model: 61-0367-87 brand: Merck Millipore Corporation
64-1070-95 [Discontinued]filling vibrator K-31
Analyzer, Testing Equipment

64-1070-95 [Discontinued]filling vibrator K-31

model: 64-1070-95 brand: Kiriyama glass Co.