61-0250-29 [Discontinued]Opticap XLT10 Durapore 0.22μm 1In. HB/HB; 1/Pk 1ST KVGLA1TBB1
Analyzer, Testing Equipment

61-0250-29 [Discontinued]Opticap XLT10 Durapore 0.22μm 1In. HB/HB; 1/Pk 1ST KVGLA1TBB1

model: 61-0250-29
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-29Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-29
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.69
  • Filter bore diameter, μm: 0.22
  • Length, cm (inch): 10
  • Length, Inch (cm): 10 (25)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 25mm (1in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XLT10 Durapore 0.22μm 1in. HB/HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    13.3mL/min @ 280kPa (40 psig) in water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 25


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Conform to USP Oxidizable Substances Test after flashing with next water ?1L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

63-1395-85 Process Reactor with Calorimetry DDS-2000A
Analyzer, Testing Equipment

63-1395-85 Process Reactor with Calorimetry DDS-2000A

model: 63-1395-85 brand: TOKYO RIKAKIKAI CO., LTD.
61-0195-19 Ultrafree-Mc HV 0.45μm 25/Pk 25PK UFC30HV25
Analyzer, Testing Equipment

61-0195-19 Ultrafree-Mc HV 0.45μm 25/Pk 25PK UFC30HV25

model: 61-0195-19 brand: Merck Millipore Corporation
4-2735-01 Phase contrast microscope 100 to 1000 × binocular PMP38B