61-0249-11 [Discontinued]Opticap XL10 Multimedia 0.5/0.22μm 3/4In TC/TC 1/Pk 1ST KV06A10FF1
Analyzer, Testing Equipment

61-0249-11 [Discontinued]Opticap XL10 Multimedia 0.5/0.22μm 3/4In TC/TC 1/Pk 1ST KV06A10FF1

model: 61-0249-11
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0249-11Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0249-11
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.69
  • Filter bore diameter, μm: 0.5 / 0.22
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, cm (inch): 33.5 (13.2)
  • Length, Inch (cm): 10 (25)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Pre-filter material: Cellulose mixed ester
  • Vent cap material: Polypropylene
  • Material: Cellulose mixed ester; hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 19mm (3/4in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XL10 multimedia 0.5/0.22μm 3/4in. TC/TC
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Air diffusion flow rate, 23 °C:


    13.3mL/min @ 280kPa (40 psig) in water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 103 (15) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Highest operating temperature, ℃: 80 °C
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 50


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 5L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

3-6727-01 Membrane Filter Sterilized 0.22μm White MFWG4722
Analyzer, Testing Equipment
61-0342-52 2,2'-Thiodiacetic Acid for Synthesis 808625 250G 8.08625.0250
Analyzer, Testing Equipment
60-3358-06 [Discontinued]Membrane Air Dryer DM Type
Analyzer, Testing Equipment