Spec

  • Unit control only possible # 1: –
  • Thermoblock: Silver
  • Sample volume: 96×0.2 mL PCR tube, 1×PCR plate 8×12
  • Heating Technology: Peltier Element, Triple Circuit Technology
  • Temperature control mode: fast, normal, safe
  • Block temperature control range: 4–99°C
  • Slope Range: 1–20°C
  • Intuitive graphic programming: Yes
  • Gradient Temperature Control Range: 30–99°C
  • Block homogeneity 20–72°C: ≤±0.3°C
  • Control accuracy: ±0.2°C
  • Email Notification: Yes
  • Flexible Lid ® Concept: ○
  • 2 Year Warranty: Yes
  • Silver Block: Yes
  • Slope Block: Yes
  • The unit can control two other units in the network: Yes
  • USB port: Yes
  • Block homogeneity 90°C: ≤±0.4°C
  • Heating rate: 5°C/second * 2
  • Cooling rate: 3.5°C/second * 2
  • Gradient Block: 12 Rows or More (0.2 mL)
  • Lid Down Slope: flexlid® technology w/TSP
  • Lid temperature range: 37–110°C
  • Interfaces: CAN_in/CAN_out, Ethernet, USB
  • Power: 110 V, 50–60 Hz
  • Maximum power consumption: 540 W
  • Total weight: 10.9 kg
  • Dimensions (W x D x H): 25 x 41.2 x 32.1 cm
  • Programs per device: >700
  • Remote Device Monitoring and Notification (VisioNize®): VisioNize® boxable
  • *1 Control from Mastercycler ® nexus, Mastercycler® nexus gradient, Mastercycler® nexus GSX1, Mastercycler® nexus SX1, Mastercycler® nexus GX2, Mastercycler® nexus X2 or Mastercycler® nexus flat
  • *Measure in two blocks

Related product recommendations

You may also be interested in the following products

62-8392-23 [Discontinued]Anti-Src, clone GD11, agarose; 200 μg 16-186
Analyzer, Testing Equipment
61-0357-88 [Discontinued]Norbornene (Stabilizer Included) for Synthesis 818796 250G 8.18796.0250
Analyzer, Testing Equipment
61-0232-85 [Discontinued]Quikscale Column GAP 300X550 1/Pk 1ST GA301511
Analyzer, Testing Equipment
61-0386-45 [Discontinued]Fmoc-Abu-OH 852048 5G 8520480005
Analyzer, Testing Equipment

61-0386-45 [Discontinued]Fmoc-Abu-OH 852048 5G 8520480005

model: 61-0386-45 brand: Merck Millipore Corporation