![61-0167-34 [Discontinued]BioSpectrometer fluorescence 6137 000.014](https://www.jgauge.com/wp-content/uploads/2025/08/fbd68770ce0df830e9831f0b13c3a6da.webp)
Analyzer, Testing Equipment
61-0167-34 [Discontinued]BioSpectrometer fluorescence 6137 000.014
Product Description
Product Model: 61-0167-34Product Brand: Eppendorf AG Fe […]
Contact Us
Product Details
Product Model: 61-0167-34
Product Brand: Eppendorf AG
Features
- Biospectrometer series that can scan at continuously variable wavelength
- Fluorescent model that can measure fluorescence intensity
- All functions of Biospectrometer Basic are available. Since both absorbance measurement and fluorescence intensity can be measured, highly sensitive determination of samples beyond the detection range of absorbance measurement with a fluorescent reagent is possible on a single device. For example, in the case of DNA, the measured concentration range is expanded by 1000 times.
- The wavelength can be freely selected in the entire spectral range (Biospectrometer Series: 1 nm increments)
- The program is pre-installed and ready to ***.
- Compact A3 size, no PC connection required
- Data can be exported to a USB memory or PC
- Results can be printed directly (optional DPU-S445 thermal printer required separately)
- Extremely long-life xenon flash lamp
- Help box for step instructions in 6 languages (including Japanese)
- Both trace measurement cuvettes and standard cuvettes can be ***d
Spec
- Light source (light absorption): Xenon flash lamp
- Light Source (Fluorescent): LED
- Ray Height: 8.5 mm
- Optical system (absorption): single beam absorption spectrum measurement using a reference beam.
- Optical system (fluorescence): confocal fluorometry using a reference beam
- Detector (Absorption): CMOS photodiode array
- detector (fluorescent): photodiode
- Wavelength Range (Absorption): Scanning (nm): 200 to with 830, 1 nm increments
- Excitation wavelength: 470 nm, bandwidth: 25 nm
- Fluorescence wavelength:
- 520 nm, Bandwidth: 15 nm
- 560 nm, Bandwidth: 40 nm
- Bandwidth (absorption): < 4 nm
- Absorbance measurement range: 0A to 3.0 A (260 nm)
- Fluorescence intensity measurement range: 0.5 nM to 2000 nM Fluorescein (fluorescence wavelength: 520 nm)
- dsDNA concentration range: 1.0 pg/μL to 1500 ng/μL
- Interface:
- USB Master: For USB Memory, Thermal Printer
- USB slave: for PC connection
- RS -232 C: For thermal printers
- Size (W x D x H): 295 x 400 x 150 mm
- Weight: 5.4 kg
- continuous wavelength measurement
- fluorometry
Related product recommendations
You may also be interested in the following products
62-8514-80 Anti-CD44, (human/mo***), violetFluor(TM) 450, clone IM7 Antibody MABF1562
model: 62-8514-80
brand: Sigma Aldrich Japan(Millipore)
61-0374-85 [Discontinued]5-Hydroxyindole for Synthesis 841110 1G 8.41110.0001
model: 61-0374-85
brand: Merck Millipore Corporation
62-8513-24 [Discontinued]Anti-CD22 Antibody, clone CY34 MABF980
model: 62-8513-24
brand: Sigma Aldrich Japan(Millipore)
62-8514-38 [Discontinued]Anti-mo*** IFN gamma, FITC, clone XMG1.2 Antibody MABF1517
model: 62-8514-38
brand: Sigma Aldrich Japan(Millipore)