Analyzer, Testing Equipment
3-5073-01 Energy Dispersive Fluorescence X-Ray Analysis Device EDX-7000
model:
3-5073-01
category:
Analyzer, Testing Equipment
Product Description
Product Model: 3-5073-01 Features Specimens of up to 30 […]
Contact Us
Product Details
Product Model: 3-5073-01
Features
- Specimens of up to 300 x 275 x about 100 mm can be set.
- You can easily set the analysis position while checking the camera image.
- High-performance SDD detector, which does not require the supply of liquid nitrogen, enables high sensitivity and high speed analysis.
Spec
- Model number: EDX-7000
- Size (mm): 460 x 590 x 360
- Weight (kg): Approx 45
- Set content: Body, PC for control
- Measurement principle: Fluorescence X-ray analysis method
- Measuring method: Energy dispersive type
- Measurement target: Solid, Liquid, Powder
- Measurement range: 11Na - 92U
- Sample chamber size: Maximum 300 x 275 x approx. 100mm
- Maximum sample weight: 5kg *1
- Cooling method: Air cooling (with fan)
- Irradiation area: φ1・3・5・10mm
- Primary filter: 5 types + OPEN
- Type: Silicone drift detector (SDD)
- Measurement atmosphere: Atmospheric air
- Sample observation: CMOS camera
- Power supply: Single-phase AC100V 50/60Hz
- Power cord length: 2.5m
- Measurement principle: Fluorescence X-ray analysis method
- Measuring method: Energy dispersive type
- Measurement target: Solid, liquid, powder
- Measurement range: 11Na - 92U
- Sample chamber size: Maximum 300 x 275 x approx. 100mm
- Maximum sample weight: 5kg *when using turret, Sample/200g, Total weight/2.4kg
- Cooling method: Air cooling (with fan)
- Irradiation area: φ1・3・5・10mm
- Primary filter: 5 types + OPEN
- Type: Silicone drift detector (SDD)
- Measurement atmosphere: Atmospheric air
- Sample observation: CMOS camera
- Power supply: Single-phase AC100V 50/60Hz
- Power cord length: 2.5m
- *We have 3 type screening analysis kit (for RoHS, for RoHS + chlorine, for RoHS + chlorine + antimony) ideal for screening analysis. Please contact with us separately. *12 samples turret, vacuum exhaust, helium replacement are optional.
Related product recommendations
You may also be interested in the following products
62-8460-89 [Discontinued]Anti-HDAC1; 50 μL ABE260
model: 62-8460-89
brand: Sigma Aldrich Japan(Millipore)
62-8483-47 Milli-Mark(R) Anti-monomethyl-Histone H3 (Lys9)-FITC; 100 tests FCABS384F
model: 62-8483-47
brand: Sigma Aldrich Japan(Millipore)
62-8519-19 Anti-G6PD, clone 2H7 MABN696
model: 62-8519-19
brand: Sigma Aldrich Japan(Millipore)
62-8516-55 [Discontinued]Anti-Huntingtin, clone 4A4.2; 100 μg MABN60
model: 62-8516-55
brand: Sigma Aldrich Japan(Millipore)