89-6646-26 NanoPhotometer NP80 Microspectrophotometer (with LCD touch screen) NP80-TOUCH
Product Description
Product Model: 89-6646-26Product Brand: IMPLEN Features […]
Contact Us
Product Details
Product Model: 89-6646-26
Product Brand: IMPLEN
Features
- Overview: [Sample Compression Technology] [True Path Technology] enables extremely simple and accurate measurements without the need for dilution.
- [Sample Compression Technology]: The unique technology of sandwiching the sample between the optical path window and mirror enables reliable measurement without dep***ing on the surface tension of the sample. High concentration and high reproducibility measurement can be performed with a trace sample of at least 0.3uL. It also supports the measurement of protein solutions containing surfactants and high concentration buffers. The evaporation prevention structure also supports the measurement of volatile samples.
- True Path Technology: Automatically selects the optimum optical path length based on the absorbance of the sample. Two high-precision optical paths (Dilution rate: 1/15, 1/140) cover a wide range of dynamic ranges.
- High-*** model equipped with all micromeasurement, general-purpose cuvette and vortex.
- It has an LCD touch screen and can be ***d standalone.
Spec
- trace/cuvette measurement model
- < General Specifications >
- External Dimensions: 200 (W) x 290 (D) x 200 (H) mm (Including Touch Screen)
- Weight: 3.8~5.2 kg (dep***ing on configuration)
- Power: 90~250 V, 50/60Hz, 60 W
- Display: 1024 x 600 pixels
- Certification: CE, IEC 61010-1:2012, EN 61326-1:2013
- In/Out Ports: USB A x 2, USB B, HDMI, Ethernet, Wireless LAN
- Other data input: USB mo***, USB keyboard
- security: Kensington slots
- optical system specification
- Wavelength Scan Range: 200~900 nm
- Measurement time: 3.5~6.0 seconds
- Wavelength reproducibility: ±0.2 nm
- Wavelength accuracy: ±0.75 nm
- Bandwidth: 1.8 nm or more
- Stray light: <0.5% 240 nm when using Nal, <1% 280 nm when using acetone
- Measurement repeatability: <0.002 A (optical path length 0.67 mm) when using 280 nm
- Accuracy of measurement: <1.75% 0.7 A (optical path length 0.67 mm) when using 280 nm
- 0 stability: +/- 0.003 A/hour (20 minutes after warm-up when using 280 nm)
- Noise: 0.002 A rms(0 A when using 280 nm), 0.002 A (pk-pk) (0 A when using 280 nm)
- Optics: 1 x 3648 CCD Array
- Light source: xenon flash lamp
- Light source life: 10^9 flashes or more than 10 years
- < During micromeasurement >
- Detection range/dsDNA: 1 ng/μL to 16,500 ng/μL
- Detection range/BSA: 0.03 mg/mL to 478 mg/mL
- Minimum sample volume: 0.3 μL
- Measuring range: 0.02~330 A
- Optical path length: 0.67, 0.07 mm
- Dilution rate: 1/15, 1/140
- Vortex mixer: 2800rpm
- < During cuvette measurement >
- Detection range/dsDNA: 0.1 ng/μL to 130 ng/μL
- Detection range/BSA: 0.003 mg/mL to 3.7 mg/mL
- Measuring range: 0~2.6 A
- Optical path center height (Z): 8.5 mm
- Cell Type: Outer Dimensions 12.5 x 12.5 mm
- Temperature control: 37°C±0.5°C
Related product recommendations
You may also be interested in the following products
62-8504-24 Anti-TERT (human), clone 2C4; 100 μL MABD55
model: 62-8504-24
brand: Sigma Aldrich Japan(Millipore)
61-0315-67 M Color Test(TM) Manganese Test (Refill Pack) for Refill (114768)/(114406) Mcolortest(TM) 118460 120Tests 1.18460.0002
model: 61-0315-67
brand: Merck Millipore Corporation