65-0576-23 Aluminum block catalyst screening container with stirrer for constant temperature bath 1.5 ~ 7.0 mL x 6 HIP-7506
Analyzer, Testing Equipment

65-0576-23 Aluminum block catalyst screening container with stirrer for constant temperature bath 1.5 ~ 7.0 mL x 6 HIP-7506

model: 65-0576-23
brand: TOKYO RIKAKIKAI CO., LTD.

Product Description

Product Model: 65-0576-23Product Brand: TOKYO RIKAKIKAI […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 65-0576-23
Product Brand: TOKYO RIKAKIKAI CO., LTD.

Features

  • Rapid and Economical Catalytic Reaction Screening Container for Reducing the Cost of Combichem Synthesis
  • SynFlexTM Catalyst screening container for aluminum block thermostatic bath with stirrer. By using this container, atmospheric pressure and high-pressure reaction screening can be easily performed.
  • Since high-throughput screening can be performed easily, the cost of equipment installation during large-scale research can be reduced.
  • The container has a temperature sensor insertion hole for monitoring and controlling the temperature. Reflux of the cold finger prevents solvent loss.
  • The vial can be set in the vessel hole in a short time to achieve a uniform temperature in the atmosphere.
  • After manual gas replacement (vacuuming + inert gas filling) with a ball valve and a pressure gauge, reactant gases (such as hydrogen) can be filled.

Spec

  • Composite Scale: 1.5 ~ 7.0 ml x 6
  • Maximum working pressure: 5 MPa (at 230 degrees C)
  • Container dimensions (mm): diameter 75 (cylindrical part)
  • Operating temperature range: Room temperature to 230 degrees Celsius (excluding when using septum)
  • Stirring system: Magnetic stirrer (RCH -1000 type)
  • Features:
  • Reflux: Cold finger (return with tap or cooling water)
  • Gas replacement: Ball valve (3-way type for switching) + pressure gauge
  • Pressure indication and relief valve: Filling of reactant gas after purging - 100/0/2400 kPa, Relief adjustment range: 0.34 ~ 2.41 MPa
  • Standard:
  • Others: With temperature sensor insertion hole, positioning hole
  • Container dimensions (mm): height 110 (without protrusions), body cylinder: phi 75 x 44 H
  • Vial: 10 mL vial
  • Dimensions (mm): phi 20 x 70 H with TS 14/23
  • Stirrer dimensions (mm): phi 5 x 15
  • Connection Diameter: Cold Water Connection Port/Purge Port: Outer Diameter 7.62 mm Hose Port, Reactive Gas Inlet: Outer Diameter 1.58 mm (1/16 ") Hose made of SUS 316
  • Wetted part materials: SUS 316 (Body, Cover), Viton (O-ring), EPDM (relief valve seal), Glass (vial)
  • *Use a single-holder BBS -1 HLD to heat the container.
  • *The O-ring made by Perfro ® needs to be replaced for temperatures above 200 degrees Celsius.
  • *The EPDM O-ring must be replaced when circulating cooling water below 0 degrees Celsius.
  • *Vials and stirrers are sold separately.
  • *Dep***ing on the sample and conditions of ***, this may fall under the Ministry of Economy, Trade and Industry's High Pressure Gas Safety Act.
  • *Reflux at low temperatures requires a cooling water circulator.
  • *Conversion of the pressure gauge and spring kit is required to operate at 5 MPa.
  • Code: 248370

Related product recommendations

You may also be interested in the following products

61-0242-94 Opticap XLT10 Polysep II 1/0.2/0.1μm 5/8In. HB/HB 1/Pk 1ST KGW1A1THH1
Analyzer, Testing Equipment
61-6429-84 [Discontinued]COL-CTRGE ANALYTICAL PAH 10 x 2.1mm PK3 N9303682
Analyzer, Testing Equipment
61-0269-63 Prostak Filt Mod VVPP 0.1μm 10-Stack 0.84m2 1/Pk 1ST PSVVAG101
Analyzer, Testing Equipment
61-0348-64 [Discontinued]2-Fluorobenzaldehyde for Synthesis 814714 50mL 8.14714.0050
Analyzer, Testing Equipment