61-6986-10 Photodiode Amplifier Operation Ambient Temperature 0℃-40℃ PDA-1
Analyzer, Testing Equipment

61-6986-10 Photodiode Amplifier Operation Ambient Temperature 0℃-40℃ PDA-1

model: 61-6986-10
brand: SIGMAKOKI CO., LTD.

Product Description

Product Model: 61-6986-10Product Brand: SIGMAKOKI CO., […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-6986-10
Product Brand: SIGMAKOKI CO., LTD.

Features

  • A transimpedance amplifier that converts weak photodiode output current into voltage.
  • Highly sensitive and fully compatible with external operation by PC, etc.
  • PDA-1: (1) There are 6 conversion ranges with an extremely large conversion ratio of 10^5 ~10^10 (V/A) to detect faint light. ② In addition to operation and output from the panel, it is also possible to connect a commercially available PC via the RS232C, change the range by a command from the PC, and obtain current values. ③ It has excellent compatibility with measurement and control software such as SGEMCS and SGTERM. ④ By using a dedicated photodiode, the temperature of the photodiode can be controlled and weak light can be detected stably.
  • Dedicated Photodiode (Optional) PDA-PD-1: (1) The PDA-PD-1 has a built-in Peltier element, amplifier, temperature control circuit, and photodetector. ② The Peltier element keeps the photodiode cool. ③ An ND filter for adjusting the amount of light received can be installed. ④ Absorbent fixed ND filter can be ***d. ⑤ The cable length to the amplifier is approximately 500 mm. ⑥ The structure is not affected by ambient noise.

Spec

  • [ Common specification]
  • Operation temperature: 0℃ - 40℃ (excluding sensor unit)
  • Amplifier gain range 0: 10^5V/A
  • Amplifier gain range 1: 10^6V/A
  • Amplifier gain range 2: 10^7V/A
  • Amplifier gain range 3: 10^8V/A
  • Amplifier gain range 4: 10^9V/A
  • Amplifier gain range 5: 10^10V/A
  • Analog maximum output voltage load 2kΩ: 4V
  • Measurement gain error (at range 0 - 3): 2% of the maximum light receiving quantity within the range
  • Measurement gain error (at range 4): 3% of the maximum light receiving quantity within the range
  • Measurement gain error (at range 5): 4% of the maximum light receiving quantity within the range
  • Cut-off frequency (at range 1): 3kHz
  • Cut-off frequency (at range 3): 30Hz
  • Cut-off frequency (at range 5): 0.3Hz
  • A/D Converter conversion frequency: 16Hz
  • A/D Converter resolution: 24 bit (However, it is 16 bit that is in effect)
  • Temperature control temperature: ?10℃ (Photo diode)
  • Temperature control fluctuation temperature: 0.1℃ (Photo diode)
  • Peltier output current: 1A (Photo diode)
  • [Individual specification]
  • Operating ambient temperature: 0℃ - 40℃
  • Storage ambient temperature: -20℃ - 60℃
  • Ambient humidity: 20 - 90% RH (non-condensing)
  • Outer dimensions: (W) 150 x (H) 50 x (D) 200mm (excluding projections)
  • Interface: RS232C, Signal output connector, etc. Our company’s temperature control connector for photodiode, Photodiode signal input connector (Note: PD and photodiode should be grounded by the anode grounding)
  • Accessories: AC adapter (AC 100V)
  • light-receiving surface size: ?
  • Electric and optical characteristics (ambient temperature 25℃) sensitivity wavelength range: ?
  • Electric and optical characteristics (ambient temperature 25℃) maximum sensitivity wavelength: ?

Related product recommendations

You may also be interested in the following products

61-0331-65 (+)-Cinchonine for Optical Resolution for Synthesis 802506 100G 8.02506.0100
Analyzer, Testing Equipment
62-8354-92 Millipore Express SHF Optiscale 25mm 0.2μm NB 6/pk SGEPA25NB6
Analyzer, Testing Equipment

62-8354-92 Millipore Express SHF Optiscale 25mm 0.2μm NB 6/pk SGEPA25NB6

model: 62-8354-92 brand: Sigma Aldrich Japan(Millipore)
62-8372-51 Anti-CRMP1, clone Y21; 100 μL 05-706
Analyzer, Testing Equipment

62-8372-51 Anti-CRMP1, clone Y21; 100 μL 05-706

model: 62-8372-51 brand: Sigma Aldrich Japan(Millipore)
62-8379-75 JAK2 Inhibitor X, FLLL32 5.30153.0001
Analyzer, Testing Equipment

62-8379-75 JAK2 Inhibitor X, FLLL32 5.30153.0001

model: 62-8379-75 brand: CBC(Merck)