61-6948-91 Pellin Broca Prism PBPQ-30L20-10
Analyzer, Testing Equipment

61-6948-91 Pellin Broca Prism PBPQ-30L20-10

model: 61-6948-91
brand: SIGMAKOKI CO., LTD.

Product Description

Product Model: 61-6948-91Product Brand: SIGMAKOKI CO., […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-6948-91
Product Brand: SIGMAKOKI CO., LTD.

Features

  • Perrin Brocker Prism is a kind of Brewster Dispersion Prism, which has a characteristic of emitting at right angles to the direction of incidence.
  • When the YAG laser is injected at the Brewster angle, the fundamental wave (1064 nm) and the double wave (532 nm) can be separated.
  • Beca*** the Brewster angle and critical angle are ***d, there is no loss due to reflection, resulting in high transmittance.
  • The Perambrocka prism has no coating and can be ***d with high-energy pulsed lasers.
  • Use to match the angle at which the light intensity of the fundamental (invisible) or double (green) YAG beam reflected at the prism incidence plane is minimized (Brewster angle).
  • Convert the polarization direction of the laser beam so that it is parallel to the bottom of the prism.
  • It can also be ***d for the spectroscopy of Ar laser with multi-wavelength oscillation.
  • * The emission beam of the ultraviolet wavelength is not reflected beca*** it deviates from the Brewster angle.
  • * It can also be ***d as a non-polarized dispersion prism, but it will not emit light at right angles to the angle of incidence unless it is made incident at the Brewster angle.
  • * Spectroscopy is possible even when an S-polarized laser beam is injected, but reflection loss occurs at the incident and outgoing surfaces.
  • * Fingerprints and dirt on the uncoated surface will prevent total reflection and no reflection.
  • * Do not let anything come in contact with the no-coat surface.
  • * Measured dimensions A and B include chamfers, so they are slightly shorter.
  • * The tolerance is defined at the intersection of each face without chamfers.

Spec

  • [ common specification]
  • Material: Synthetic quartz
  • Design wavelength: 706nm (midway between 1063nm to 532nm)
  • Angle accuracy: <3′
  • Base material surface accuracy: λ/10
  • Scratch - dig: 20?10
  • Effective range: Ellipse inscribed in a rectangular of 90% of the dimensions
  • [Individual specification]
  • A: 30mm
  • B: 50mm
  • C: 20mm
  • θ1: 56.13°
  • θ2: 79.5°
  • RoHS conform product

Related product recommendations

You may also be interested in the following products

62-8518-46 Anti-mGluR5 Antibody, clone N75/33 , Cat. No. MABN540 MABN540
Analyzer, Testing Equipment

62-8518-46 Anti-mGluR5 Antibody, clone N75/33 , Cat. No. MABN540 MABN540

model: 62-8518-46 brand: Sigma Aldrich Japan(Millipore)
62-8425-19 ITK Inhibitor, BMS-509744 419820-5MG
Analyzer, Testing Equipment

62-8425-19 ITK Inhibitor, BMS-509744 419820-5MG

model: 62-8425-19 brand: CBC(Merck)
61-0205-07 Q-GARD T1 PACK (1/PK) 1ST QGARDT1X1
Analyzer, Testing Equipment

61-0205-07 Q-GARD T1 PACK (1/PK) 1ST QGARDT1X1

model: 61-0205-07 brand: Merck Millipore Corporation
61-0276-71 Optiscale Caps Filt Milligard 1.2/0.5μm 3/4In.Tc/Tc 3/Pk 3 x 1ST SWSCA47FF3
Analyzer, Testing Equipment