61-6927-65 YAGLaser Focusing Lens Focal Length 20mm NYTL-25-20PY1
Analyzer, Testing Equipment

61-6927-65 YAGLaser Focusing Lens Focal Length 20mm NYTL-25-20PY1

model: 61-6927-65
brand: SIGMAKOKI CO., LTD.

Product Description

Product Model: 61-6927-65Product Brand: SIGMAKOKI CO., […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-6927-65
Product Brand: SIGMAKOKI CO., LTD.

Features

  • This is an air-gap type acromatic condensing lens with no adhesive attached to the lens.
  • It is ***d as a condensing lens for a 532 nm high-power laser machine with a built-in coaxial epi-illumination observation system.
  • Chromatic aberration is corrected in a wide wavelength range centered around 532 nm by optimization based on lens design.
  • For lenses with a focal length of 60 mm or more, laser collimation can be narrowed down to a spot diameter that is almost diffraction limited.
  • Since the lens is coated with an anti-reflection film, the loss of light due to reflection is small, and the beam can be concentrated efficiently.
  • A separately sold protective glass can be installed to protect the lens from flying light ca***d by laser processing.
  • A special lens holder (LHF-M34-30) is available for fixing the condenser lens.
  • * Use the condenser lens when you want to focus an object at infinity, or when you want to *** the point light source as parallel light.
  • Sufficient optical performance cannot be obtained when the camera is ***d for close-range imaging.
  • * The condenser lens has an orientation that allows light to enter.
  • * Be sure to allow parallel light to enter from the upper side (look at the engraving on the side of the lens barrel upright).
  • * Doing so can ca*** chromatic aberration and spherical aberration to become large, which can increase the size of the focus spot, and can ca*** blurred images.
  • If you *** the instrument outside the specified wavelength range, chromatic aberration may increase and transmittance may be reduced.
  • * When using with a high-power laser or near a light source that emits heat, the condenser lens may become hot and the focal length of the condenser lens may change.
  • * Heat dissipation measures are necessary when irradiating for a long time.
  • * If you want to reduce the condensing spot diameter, widen the incident beam diameter (1/e^2) to about half the effective diameter of the condensing lens.

Spec

  • [

    common specification]
  • Material: Crown series glass - (air gap) - flint series glass
  • Frame material: Aluminum surface treatment: Black anodic oxide
  • Design wavelength: 1064nm, 632.8nm
  • Coating: 1064nm, for 632.8nm reflective prevention film
  • Incident allowable angle: ±1°
  • Laser durability: 1J/cm2 (pulse width 10ns, Repeat frequency 20Hz)
  • [Individual specification]
  • Lens outer diameter φD: φ25mm
  • Focus distance f: 20mm
  • Outer diameter φDc: φ32mm
  • Effective diameter φDe: φ20mm
  • Length L: 22mm
  • Screw for fixing Ma: M29 P0.75
  • Mounting screw Mb: M22 P0.75
  • Screw length A: 6mm
  • NA : 0.5
  • WD: 9mm
  • RoHS conform product

Related product recommendations

You may also be interested in the following products

62-8426-31 Lactacystin, Synthetic 426100-200UG
Analyzer, Testing Equipment

62-8426-31 Lactacystin, Synthetic 426100-200UG

model: 62-8426-31 brand: CBC(Merck)
62-8363-31 Durapore .22um WH PL 63.5MM 25/PK GVWP06225
Analyzer, Testing Equipment

62-8363-31 Durapore .22um WH PL 63.5MM 25/PK GVWP06225

model: 62-8363-31 brand: Sigma Aldrich Japan(Millipore)
61-0321-19 Phenol Red (Alias: Phenolsulfonphthalein) Reag. pH Eur 159375 1G 1.59375.0001
Analyzer, Testing Equipment
62-8394-22 ChIPAb+(TM) Acetyl Histone H3 (Lys23); 25 assays 17-10112
Analyzer, Testing Equipment

62-8394-22 ChIPAb+(TM) Acetyl Histone H3 (Lys23); 25 assays 17-10112

model: 62-8394-22 brand: Sigma Aldrich Japan(Millipore)