61-6884-64 Broadband Polarizing Beamsplitter 235-265nm 10mm PBSW-10-250
Analyzer, Testing Equipment

61-6884-64 Broadband Polarizing Beamsplitter 235-265nm 10mm PBSW-10-250

model: 61-6884-64
brand: SIGMAKOKI CO., LTD.

Product Description

Product Model: 61-6884-64Product Brand: SIGMAKOKI CO., […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-6884-64
Product Brand: SIGMAKOKI CO., LTD.

Features

  • Polarization beam splitter that widens the wavelength band for polarization separation.
  • It can be ***d for experiments using multi-wavelength lasers or continuous spectrum light sources.
  • By transmitting P-polarized light and reflecting S-polarized light, the polarization state of the incident light can be divided into orthogonal components.
  • Since a dielectric multilayer film is ***d for coating, light loss is small and polarization can be separated efficiently.
  • Since it is a cube type, the optical axis of the emitted light will not be translated if the beam is incident perp***icularly. Also, even if a beam of the same size as the effective diameter is injected, the transmitted or reflected light will not be lost or reduced.
  • In combination with a polarizer and a broadband 1/2 wavelength plate, it is possible to make a variable light quantity branching device indep***ent of wavelength.
  • A Grantomson Prism (GTPC) with a high extinction ratio is also available.
  • * The characteristics of transmittance and extinction ratio may change if light enters from the prism side which is not marked with ○.
  • * The extinction ratio of reflected light is slightly lower than that of transmitted light.
  • * Wavelength dispersion occurs in transmitted and reflected light due to the refractive index of the material and the thickness of the glass. In addition, chromatic aberration and spherical aberration may occur when a converging or diverging beam is injected.

Spec

  • [

    common specification]
  • Material: BK7, SK2, SF15, Synthetic quartz
  • Base material surface accuracy: λ/4
  • Transmitted beam polarization angle: <10′
  • Coating: Slope dielectric multi-layered film, Side 4 surfaces reflective prevention film
  • Incident angle: 0°
  • Laser durability (reference value): 0.3J/cm2 (pulse width 10ns, Repeat frequency 20Hz)
  • Scratch - dig: 20-10
  • Effective range: Circle inscribed to 85% of outer dimensions of square
  • [Individual specification]
  • Adaptive wavelength: 235 - 265nm
  • A=B=C: 10mm
  • Material: Synthetic quartz
  • P-polarized light transmittance: >85%
  • S polarized light reflective ratio: >90%
  • Transmission extinction ratio Ts: Tp: 1: 100
  • RoHS conform product

Related product recommendations

You may also be interested in the following products

61-0251-35 Opticap XL2 Durapore 0.1μm 1-1/2In. TC/TC; 3/Pk 3 x 1ST KVVLA02TT3
Analyzer, Testing Equipment
61-0199-78 Ultrafree-Cl DV 0.65μm 25/Pk 25PK UFC40DV25
Analyzer, Testing Equipment

61-0199-78 Ultrafree-Cl DV 0.65μm 25/Pk 25PK UFC40DV25

model: 61-0199-78 brand: Merck Millipore Corporation
62-8514-15 Anti-CD161 (NK1.1) (mo***), FITC, clone PK136 Antibody MABF1490
Analyzer, Testing Equipment
61-0269-68 Pellicon XL UF Mod Biomax 8 Kd 0.005m2 1/Pk 1ST PXB008A50
Analyzer, Testing Equipment

61-0269-68 Pellicon XL UF Mod Biomax 8 Kd 0.005m2 1/Pk 1ST PXB008A50

model: 61-0269-68 brand: Merck Millipore Corporation