61-6882-38 Visible Range Dichroic Miirror High Transmittance Range 535-700nm DIM-50S-BLE
Analyzer, Testing Equipment

61-6882-38 Visible Range Dichroic Miirror High Transmittance Range 535-700nm DIM-50S-BLE

model: 61-6882-38
brand: SIGMAKOKI CO., LTD.

Product Description

Product Model: 61-6882-38Product Brand: SIGMAKOKI CO., […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-6882-38
Product Brand: SIGMAKOKI CO., LTD.

Features

  • A mirror that separates the three primary colors (RGB) of light.
  • Since it ***s non-absorbing dielectric multilayers, it can *** transmitted light as well as reflected light.
  • If you also *** this transmitted light, you can *** any two of the dichroic mirrors to separate R, G, and B (Example DIM-RED+ DIM-GRE: reflection ⇒ red, reflection ⇒ green, transmission ⇒ blue).
  • Since the transition from transmission to reflection is rapid, it can also be ***d as a wavelength separation filter.
  • If the incident angle is varied by 0~45 degrees, it can also be ***d as a simple wavelength variable filter.
  • You can create white light by superimposing three RGB colors of light with a dichroic mirror.
  • B270 (R) is a registered trademark of SCHOTT AG.
  • * Do not *** with high-power laser or high-energy pulsed laser.
  • * A dichroic mirror for the pulse laser is also available.
  • * When ***d as an RGB mirror, set the angle of incidence to 45 degrees.
  • Color separation will not be performed correctly if the camera is ***d at any other angle of incidence.

Spec

  • [

    common specification]
  • Material: B270(R) (white plate glass) or BK7
  • Incident angle: 45°
  • Adaptive wavelength: 400 - 700nm
  • Scratch - dig: 60?40
  • Effective diameter: Circle inscribed to 90% of outer dimensions of square
  • [Individual specification]
  • Transmittance band wavelength (45 degrees incidence): 535 - 700nm
  • Transmittance band transmittance rate (45 degrees incidence): >85%
  • Cut-off band wavelength (45 degrees incidence): 400 - 450nm
  • Cut-off band transmittance rate (45 degrees incidence): <5%
  • Half wavelength (50%): 490±10nm
  • RoHS conform product

Related product recommendations

You may also be interested in the following products

61-0356-61 Tert-Butyldimethylchlorosilane for Synthesis 818642 25G 8.18642.0025
Analyzer, Testing Equipment
62-8428-13 Membrane Traffic Inhibitor, A5 444805-10MG
Analyzer, Testing Equipment
61-6433-79 Elite-Wax,30m,0.25mmid,0.25μm N9316403
Analyzer, Testing Equipment

61-6433-79 Elite-Wax,30m,0.25mmid,0.25μm N9316403

model: 61-6433-79 brand: PerkinElmer, Inc.
62-8517-68 Anti-NHERF-2 Antibody, clone 32B6, Cat. No. MABN385 MABN385
Analyzer, Testing Equipment

62-8517-68 Anti-NHERF-2 Antibody, clone 32B6, Cat. No. MABN385 MABN385

model: 62-8517-68 brand: Sigma Aldrich Japan(Millipore)