61-0252-64 Opticap XL2 Milligard LPB 1.2/0.5μm 3/4In. TC/TC 3/Pk 3 x 1ST KWLCA02FF3
Analyzer, Testing Equipment

61-0252-64 Opticap XL2 Milligard LPB 1.2/0.5μm 3/4In. TC/TC 3/Pk 3 x 1ST KWLCA02FF3

model: 61-0252-64
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0252-64Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0252-64
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, cm

    2

    : 700
  • Filtration area, m

    2

    : 0.07
  • Diameter, cm (inch): 12.5 (4.9)
  • Length, Inch (cm): 2 (5)
  • Support material: Polyester
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Cellulose mixed ester
  • Housing: Polypropylene
  • Filter brand name: Milligard
  • Format: Double Layer
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Substitute: KWSCL4FF3
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 19mm (3/4in.) sanitary flange
  • Quantity/box: 3
  • Overview: Opticap XL2 Milligard low protein absorption 1.2/0.5μm 3/4in. TC/TC
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Nominal bore diameter, μm: 1.2 / 0.5
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): 345 (50) @ 25


    °C
  • Sterilization: Autoclave sterilization 3 times for 30 minutes at 121℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 60


    mg per capsule after a 1


    L flush and 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Conform to USP Oxidizable Substances Test after flashing with next water ?1L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0387-19 [Discontinued]Fmoc-Tyr(2-Cltrt)-OH 852080 25G 8520800025
Analyzer, Testing Equipment
64-1179-64 Filter Paper No. 327, 280mm 100 pcs/pack 3801280
Analyzer, Testing Equipment
62-8394-41 LentiBrite(TM) GFP-LC3 Control Mutant Lentiviral Biosensor 17-10189
Analyzer, Testing Equipment
61-0250-72 Opticap Gamma Compatible XLT20 Durapore 0.22μm GC 1.5In TC/TC 1/Pk 1ST KVGLG2TTT1
Analyzer, Testing Equipment