61-0251-52 Opticap XL10 Durapore 0.1μm 1-1/2In. TC/TC; 1/Pk 1ST KVVLA10TT1
Analyzer, Testing Equipment

61-0251-52 Opticap XL10 Durapore 0.1μm 1-1/2In. TC/TC; 1/Pk 1ST KVVLA10TT1

model: 61-0251-52
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0251-52Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0251-52
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.69
  • Filter bore diameter, μm: 0.1
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, Inch (cm): 10 (25)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Substitute: KVVL01TC1
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 38mm (1-1/2in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XL10 Durapore 0.1μm 1-1/2in. TC/TC
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Air diffusion flow rate, 23 °C:


    20mL/min at 390kPa (56psig) water-wet
  • Bubble point, 23 °C:


    483kPa (70psig) water-wet and air
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 103 (15) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 25


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Conform to USP Oxidizable Substances Test after flashing with next water ?1L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8483-40 Milli-Mark(R) Anti-acetyl-Histone H4-PE FCABS326PE
Analyzer, Testing Equipment

62-8483-40 Milli-Mark(R) Anti-acetyl-Histone H4-PE FCABS326PE

model: 62-8483-40 brand: Sigma Aldrich Japan(Millipore)
62-8381-20 Anti-Gsα; 50 μL 06-237
Analyzer, Testing Equipment

62-8381-20 Anti-Gsα; 50 μL 06-237

model: 62-8381-20 brand: Sigma Aldrich Japan(Millipore)
61-0223-71 Polygard-CN Cart Filt 10In. 1.2μm Code 7 PTFE-EV 6/Pk 6 x 1ST CN1271T06
Analyzer, Testing Equipment
62-8363-61 Adapter, 1/8 NPTM to 1/4 tube YT3009018
Analyzer, Testing Equipment

62-8363-61 Adapter, 1/8 NPTM to 1/4 tube YT3009018

model: 62-8363-61 brand: Sigma Aldrich Japan(Millipore)