61-0250-84 Opticap Gamma Compatible XL10 Durapore 0.22μm GC TC/HB 1/Pk 1ST KVGLG10FH1
Analyzer, Testing Equipment

61-0250-84 Opticap Gamma Compatible XL10 Durapore 0.22μm GC TC/HB 1/Pk 1ST KVGLG10FH1

model: 61-0250-84
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-84Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-84
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.69
  • Filter bore diameter, μm: 0.22
  • Diameter, cm (inch): 10.7 (4.2)
  • Length, cm (inch): 33.5 (13.2)
  • Length, Inch (cm): 10 (25)
  • Support material: Polyester
  • Seal material: Silicone
  • Device material: Gamma compatible polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 19mm (3/4in.) sanitary flange/14mm (9/16in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XL10 Durapore 0.22μm gamma compatible TC/HB
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Air diffusion flow rate, 23 °C:


    14mL/min at 280kPa (40psig) wetted with water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization at 126℃ for 60 minutes for 3 times; 45 kilogray (4.5 Megarad) gamma irradiation compatible; in-line steam sterilization is unavailable
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 25


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Conform to USP Oxidizable Substances Test after flashing with next water ?1L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0253-02 Opticap XL4 Milligard 1.2/0.5μm 9/16In. HB/HB 3/Pk 3 x 1ST KWSCA04HH3
Analyzer, Testing Equipment
62-8350-45 Opticap XLT10 Express SHR GC 0.5+0.1μm 1.5inTC-1inHB 1/Pk KHVEG1TTB1
Analyzer, Testing Equipment
61-0295-54 Mercury(II) Thiocyanate For Analysis GR Emsure(TM)  Reag. Ph Eur 104484 100G 1.04484.0100
Analyzer, Testing Equipment
4-4432-01 Blade Scissors Blade Length 135 mm 4163
Analyzer, Testing Equipment