61-0250-78 Opticap Gamma Compatible XLT30 Durapore 0.22μm GC 1.5In TC/TC 1/Pk 1ST KVGLG3TTT1
Analyzer, Testing Equipment

61-0250-78 Opticap Gamma Compatible XLT30 Durapore 0.22μm GC 1.5In TC/TC 1/Pk 1ST KVGLG3TTT1

model: 61-0250-78
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-78Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-78
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 2.1
  • Length from inlet to outlet, cm (inch): 15.2 (6.0)
  • Filter bore diameter, μm: 0.22
  • Length, cm (inch): 87.1 (34.3)
  • Length, Inch (cm): 30 (75)
  • Support material: Polyester
  • Seal material: Silicone
  • Device material: Gamma compatible polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Form: Capsule
  • Connection, Inlet/outlet: 38mm (1-1/2in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XLT30 Durapore 0.22μm gamma compatible -1/8in. HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    42mL/min at 280kPa (40psig) wetted with water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization at 126℃ for 60 minutes for 3 times; 45 kilogray (4.5 Megarad) gamma irradiation compatible; in-line steam sterilization is unavailable
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 75


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 3L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8465-82 Anti-ARMS2 ABN107
Analyzer, Testing Equipment

62-8465-82 Anti-ARMS2 ABN107

model: 62-8465-82 brand: Sigma Aldrich Japan(Millipore)
62-8351-12 Express PHF 3" XL TT 3/PK autoclave KPGEA03TT3
Analyzer, Testing Equipment

62-8351-12 Express PHF 3" XL TT 3/PK autoclave KPGEA03TT3

model: 62-8351-12 brand: Sigma Aldrich Japan(Millipore)
62-8369-95 Angiotensin II, Human 05-23-0101-25MG
Analyzer, Testing Equipment

62-8369-95 Angiotensin II, Human 05-23-0101-25MG

model: 62-8369-95 brand: CBC(Merck)
61-0350-45 [Discontinued]Tert-Dodecanethiol (Isomer Mixture) for Synthesis 814912 250mL 8.14912.0250
Analyzer, Testing Equipment