Spec

  • Filtration area, m

    2

    : 2.17
  • Length from inlet to outlet, cm (inch): 19.8 (7.8)
  • Filter bore diameter, μm: 0.22
  • Length, cm (inch): 87.1 (34.3)
  • Length, Inch (cm): 30 (75)
  • Support material: Polyester
  • Seal material: Silicone
  • Device material: Gamma compatible polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Form: Capsule
  • Connection, Inlet/outlet: 16mm (5/8in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XLT30 Durapore 0.22μm gamma compatible 5/8in. HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    42mL/min at 280kPa (40psig) wetted with water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization at 126℃ for 60 minutes for 3 times; 45 kilogray (4.5 Megarad) gamma irradiation compatible; in-line steam sterilization is unavailable
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 75


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 3L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8521-74 Anti-mTOR, clone F11; 100 μg MABS14
Analyzer, Testing Equipment

62-8521-74 Anti-mTOR, clone F11; 100 μg MABS14

model: 62-8521-74 brand: Sigma Aldrich Japan(Millipore)
62-8517-81 Anti-CHRDL1 clone 10C9.3 MABN453
Analyzer, Testing Equipment

62-8517-81 Anti-CHRDL1 clone 10C9.3 MABN453

model: 62-8517-81 brand: Sigma Aldrich Japan(Millipore)
61-0198-61 Stericup-Vp 0.10μm PES 250mL RS 12/Pk 12PK S2VPU02RE
Analyzer, Testing Equipment

61-0198-61 Stericup-Vp 0.10μm PES 250mL RS 12/Pk 12PK S2VPU02RE

model: 61-0198-61 brand: Merck Millipore Corporation
61-0202-83 Pyrodetect Endotoxin Standard (921300) 144161 1ST 1.44161.0001
Analyzer, Testing Equipment