61-0250-70 Opticap Gamma Compatible XLT20 Durapore 0.22μm GC 5/8In HB/HB 1/Pk 1ST KVGLG2THH1
Analyzer, Testing Equipment

61-0250-70 Opticap Gamma Compatible XLT20 Durapore 0.22μm GC 5/8In HB/HB 1/Pk 1ST KVGLG2THH1

model: 61-0250-70
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-70Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-70
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 1.45
  • Length from inlet to outlet, cm (inch): 19.8 (7.8)
  • Filter bore diameter, μm: 0.22
  • Length, cm (inch): 62.5 (24.6)
  • Length, Inch (cm): 20 (50)
  • Support material: Polyester
  • Seal material: Silicone
  • Device material: Gamma compatible polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Form: Capsule
  • Connection, Inlet/outlet: 16mm (5/8in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XLT20 Durapore 0.22μm gamma compatible 5/8in. HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    28mL/min at 280kPa (40psig) wetted with water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization at 126℃ for 60 minutes for 3 times; 45 kilogray (4.5 Megarad) gamma irradiation compatible; in-line steam sterilization is unavailable
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 50


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 2L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0213-08 Millex-HPF HV 0.45μm PVDF W/Prefilter 25mm Non-Ster 1000/Pk 1000/PK SLHVM25NK
Analyzer, Testing Equipment
63-6529-06 BD Difco (TM) BG Sulphite Agar Medium 271710
Analyzer, Testing Equipment

63-6529-06 BD Difco (TM) BG Sulphite Agar Medium 271710

model: 63-6529-06 brand: BD (Becton, Dickinson and Company)
61-0221-91 Tank Lid Seal, 10-In. Sanitary Gasket; 1 Each 1ST CMP0414
Analyzer, Testing Equipment

61-0221-91 Tank Lid Seal, 10-In. Sanitary Gasket; 1 Each 1ST CMP0414

model: 61-0221-91 brand: Merck Millipore Corporation
61-0354-85 Ethylhexadecyldimethylammonium Bromide for Synthesis 818424 100G 8.18424.0100
Analyzer, Testing Equipment