61-0250-65 Opticap Gamma Compatible XLT10 Durapore 0.22μm GC 1.5In TC/TC 1/Pk 1ST KVGLG1TTT1
Analyzer, Testing Equipment

61-0250-65 Opticap Gamma Compatible XLT10 Durapore 0.22μm GC 1.5In TC/TC 1/Pk 1ST KVGLG1TTT1

model: 61-0250-65
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-65Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-65
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.7
  • Length from inlet to outlet, cm (inch): 15.2 (6.0)
  • Filter bore diameter, μm: 0.22
  • Length, cm (inch): 37.6 (14.8)
  • Length, Inch (cm): 10 (25)
  • Support material: Polyester
  • Seal material: Silicone
  • Device material: Gamma compatible polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Form: Capsule
  • Connection, Inlet/outlet: 38mm (1-1/2in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XLT10 Durapore 0.22μm gamma compatible 1-1/2in. TC
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    14mL/min at 280kPa (40psig) wetted with water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization at 126℃ for 60 minutes for 3 times; 45 kilogray (4.5 Megarad) gamma irradiation compatible; in-line steam sterilization is unavailable
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 25


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Conform to USP Oxidizable Substances Test after flashing with next water ?1L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8394-68 LentiBrite(TM) GFP-Rad51 Lentiviral Biosensor 17-10234
Analyzer, Testing Equipment

62-8394-68 LentiBrite(TM) GFP-Rad51 Lentiviral Biosensor 17-10234

model: 62-8394-68 brand: Sigma Aldrich Japan(Millipore)
62-8526-13 Anti-Septin-9 Antibody, clone 1A6C2 MABT321
Analyzer, Testing Equipment

62-8526-13 Anti-Septin-9 Antibody, clone 1A6C2 MABT321

model: 62-8526-13 brand: Sigma Aldrich Japan(Millipore)
62-8473-29 Anti-Pro-Collagen Type I, A1/COL1A1 ABT257
Analyzer, Testing Equipment

62-8473-29 Anti-Pro-Collagen Type I, A1/COL1A1 ABT257

model: 62-8473-29 brand: Sigma Aldrich Japan(Millipore)
62-8502-52 Anti-PACS2, Clone 9F12.2 MABC598
Analyzer, Testing Equipment

62-8502-52 Anti-PACS2, Clone 9F12.2 MABC598

model: 62-8502-52 brand: Sigma Aldrich Japan(Millipore)