61-0250-63 Opticap Gamma Compatible XLT10 Durapore 0.22μm GC 5/8In HB/HB 1/Pk 1ST KVGLG1THH1
Analyzer, Testing Equipment

61-0250-63 Opticap Gamma Compatible XLT10 Durapore 0.22μm GC 5/8In HB/HB 1/Pk 1ST KVGLG1THH1

model: 61-0250-63
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-63Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-63
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.73
  • Length from inlet to outlet, cm (inch): 19.8 (7.8)
  • Filter bore diameter, μm: 0.22
  • Length, cm (inch): 37.6 (14.8)
  • Length, Inch (cm): 10 (25)
  • Support material: Polyester
  • Seal material: Silicone
  • Device material: Gamma compatible polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Form: Capsule
  • Connection, Inlet/outlet: 16mm (5/8in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XLT10 Durapore 0.22μm gamma compatible 5/8in. HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    14mL/min at 280kPa (40psig) wetted with water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization at 126℃ for 60 minutes for 3 times; 45 kilogray (4.5 Megarad) gamma irradiation compatible; in-line steam sterilization is unavailable
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 25


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Conform to USP Oxidizable Substances Test after flashing with next water ?1L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0207-56 NYLON NET FLT. 180μm 30cmx3m ROLL 1SET NY8H00010
Analyzer, Testing Equipment

61-0207-56 NYLON NET FLT. 180μm 30cmx3m ROLL 1SET NY8H00010

model: 61-0207-56 brand: Merck Millipore Corporation
1-8463-01 Sterile Syringe Filter (Supor Acrodisc) Φ13mm/0.2μm 4602
Analyzer, Testing Equipment
62-8526-17 Anti-CEACAM5 Antibody, clone 5C8C4 MABT325
Analyzer, Testing Equipment

62-8526-17 Anti-CEACAM5 Antibody, clone 5C8C4 MABT325

model: 62-8526-17 brand: Sigma Aldrich Japan(Millipore)
62-8460-27 Anti-NXF1; 100 μL ABE81
Analyzer, Testing Equipment

62-8460-27 Anti-NXF1; 100 μL ABE81

model: 62-8460-27 brand: Sigma Aldrich Japan(Millipore)