61-0250-56 Opticap XL5 Durapore 0.22μm 1-1/2In. TC-9/16In. HB; 1/Pk 1ST KVGLA05TH1
Analyzer, Testing Equipment

61-0250-56 Opticap XL5 Durapore 0.22μm 1-1/2In. TC-9/16In. HB; 1/Pk 1ST KVGLA05TH1

model: 61-0250-56
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-56Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-56
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.35
  • Filter bore diameter, μm: 0.22
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, Inch (cm): 5 (12.5)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 38mm (1-1/2in.) sanitary flange/14mm (9/16in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XL5 Durapore 0.22μm TC/HB
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Air diffusion flow rate, 23 °C:


    6.6mL/min at 280kPa (40psig) water-wet
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 103 (15) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 15


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 500mL
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8492-17 Anti-Laminin γ1 Antibody, clone 2E8 (Ascites Free) MAB1920-C
Analyzer, Testing Equipment

62-8492-17 Anti-Laminin γ1 Antibody, clone 2E8 (Ascites Free) MAB1920-C

model: 62-8492-17 brand: Sigma Aldrich Japan(Millipore)
3-9984-01 Thermal Cycler miniPCR QP-1000-01
Analyzer, Testing Equipment
62-8351-37 Express PHF 3" XL HH 3/PK gamma KPGEG03HH3
Analyzer, Testing Equipment

62-8351-37 Express PHF 3" XL HH 3/PK gamma KPGEG03HH3

model: 62-8351-37 brand: Sigma Aldrich Japan(Millipore)
61-0223-54 Polygard-CN Cart Filt 10In. 0.6μm Code 7 EP 6/Pk 6 x 1ST CN0671E06
Analyzer, Testing Equipment