61-0250-48 Opticap XL4 Durapore 0.22μm 3/4In. TC/TC; 3/Pk 3 x 1ST KVGLA04FF3
Analyzer, Testing Equipment

61-0250-48 Opticap XL4 Durapore 0.22μm 3/4In. TC/TC; 3/Pk 3 x 1ST KVGLA04FF3

model: 61-0250-48
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-48Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-48
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.19
  • Filter bore diameter, μm: 0.22
  • Diameter, cm (inch): 12.5 (4.9)
  • Length, Inch (cm): 4 (10)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Substitute: KVGL04FF3
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 19mm (3/4in.) sanitary flange
  • Quantity/box: 3
  • Overview: Opticap XL4 Durapore 0.22μm 3/4in. TC/TC
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Air diffusion flow rate, 23 °C:


    5.5mL/min at 280kPa (40psig) wetted with water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 103 (15) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 10


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 500mL
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0338-24 Nickel(II) Acetylacetonate For Synthesis 806715 25G 8.06715.0025
Analyzer, Testing Equipment
62-8419-45 Ganglioside GD1a, Disialo, Diammonium Salt, Bovine Brain 345736-1MG
Analyzer, Testing Equipment
61-9067-21 Adapter for Small Fluorescence Cell CAF-20 6220-35042
Analyzer, Testing Equipment
62-8528-67 Anti-Histidine-Tagged Protein Mo*** mAb (13/45/31/2) OB05-100UG
Analyzer, Testing Equipment