61-0250-39 Opticap XLT20 Durapore 0.22μm 5/8In. HB/HB; 1/Pk 1ST KVGLA2THH1
Analyzer, Testing Equipment

61-0250-39 Opticap XLT20 Durapore 0.22μm 5/8In. HB/HB; 1/Pk 1ST KVGLA2THH1

model: 61-0250-39
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0250-39Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0250-39
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 1.38
  • Filter bore diameter, μm: 0.22
  • Length, cm (inch): 20
  • Length, Inch (cm): 20 (50)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophilic PVDF
  • Housing: Polypropylene
  • Filter brand name: Durapore(R)
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 16mm (5/8in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XLT20 Durapore 0.22μm 5/8in. HB
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Air diffusion flow rate, 23 °C:


    26.6mL/min @ 280kPa (40 psig) in water
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 172 (25) at 80℃; reverse direction - 345 (50) at 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization 3 times for 60 minutes at 126℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 50


    mg per capsule after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 2L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

1-3208-01 Syringe Filter GF Φ13mm/1μm SYGF0305MNXX104
Analyzer, Testing Equipment
4-567-01 Staining Tray Vertical 5 Pieces GSJ5
Analyzer, Testing Equipment

4-567-01 Staining Tray Vertical 5 Pieces GSJ5

model: 4-567-01 brand: AS ONE Corporation
61-0252-87 Opticap XL10 Milligard LPB 0.5/0.2μm 1.5In. TC/TC 1/Pk 1ST KWLSA10TT1
Analyzer, Testing Equipment
62-8523-77 Anti-PI3 Kinase Antibody, p85 Antibody, N-SH3 Antibody, clone 1D5.1 MABS831
Analyzer, Testing Equipment