Spec

  • Filtration area, m

    2

    : 0.65
  • Filter bore diameter, μm: 0.2
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, cm (inch): 33.5 (13.2)
  • Length, Inch (cm): 10 (25)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophobicity PTFE
  • Housing: Polypropylene
  • Filter brand name: Aervent
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Vent/drain: 1/4in. hose port with double O-ring seal
  • Connection, Inlet/outlet: 14mm (9/16in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XL10 Aervent 0.2μm 9/16in. HB/HB
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Air diffusion flow rate, 23 °C:


    24mL/min at 96.5kPa (14psig) 70//30% IPA/water
  • Hydro-Core test:


    0.75?mL/min @ 260?kPa (38?psig)
  • Bubble point, 23 °C:


    110kPa (16psig) 70/30% IPA/water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 103 (15) at 80℃; reverse direction - 414 (60) at 25℃, intermittent
  • Wettability: Hydrophobicity
  • Sterilization: Autoclave sterilization at 135℃ for 30 minutes for 30 times; in-line steam sterilization is unavailable
  • Sterility: No sterilization
  • Nitrogen diffusion flow rate, 23 °C:


    10mL/min at 170kPa (25psig) water-wet
  • Total extract: The extractables level was equal to or less than 45


    mg after 24


    hours in a 70/30%


    IPA/water mixture at controlled room temperature.
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0225-14 Polygard-CR Cart Filt 10In. 25μm Code F 6/Pk 6 x 1ST CR25F1006
Analyzer, Testing Equipment
61-0352-51 Potassium Osmate Dihydrate for Synthesis 818055 1G 8.18055.0001
Analyzer, Testing Equipment
63-6529-08 BD Difco (TM) TT broth basal medium (Hajna) 249120
Analyzer, Testing Equipment

63-6529-08 BD Difco (TM) TT broth basal medium (Hajna) 249120

model: 63-6529-08 brand: BD (Becton, Dickinson and Company)
62-8417-66 Focal Adhesion Kinase Inhibitor I 324877-5MG
Analyzer, Testing Equipment