61-0249-06 Opticap Sterilizing Grade XL10 Aervent 0.2μm 9/16In HB/HB 1/Pk 1ST KTGRA10HH1
Analyzer, Testing Equipment

61-0249-06 Opticap Sterilizing Grade XL10 Aervent 0.2μm 9/16In HB/HB 1/Pk 1ST KTGRA10HH1

model: 61-0249-06
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0249-06Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0249-06
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.65
  • Filter bore diameter, μm: 0.2
  • Diameter, cm (inch): 14.5 (5.7)
  • Length, cm (inch): 33.5 (13.2)
  • Length, Inch (cm): 10 (25)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophobicity PTFE
  • Housing: Polypropylene
  • Filter brand name: Aervent
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Vent/drain: 1/4in. hose port with double O-ring seal
  • Connection, Inlet/outlet: 14mm (9/16in.) hose port
  • Quantity/box: 1
  • Overview: Opticap XL10 Aervent 0.2μm 9/16in. HB/HB
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Air diffusion flow rate, 23 °C:


    24mL/min at 96.5kPa (14psig) 70//30% IPA/water
  • Hydro-Core test:


    0.75?mL/min @ 260?kPa (38?psig)
  • Bubble point, 23 °C:


    110kPa (16psig) 70/30% IPA/water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 103 (15) at 80℃; reverse direction - 414 (60) at 25℃, intermittent
  • Wettability: Hydrophobicity
  • Sterilization: Autoclave sterilization at 135℃ for 30 minutes for 30 times; in-line steam sterilization is unavailable
  • Sterility: No sterilization
  • Nitrogen diffusion flow rate, 23 °C:


    10mL/min at 170kPa (25psig) water-wet
  • Total extract: The extractables level was equal to or less than 45


    mg after 24


    hours in a 70/30%


    IPA/water mixture at controlled room temperature.
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-4430-35 SPC Glass Base for Φ90mm 061680-9023
Analyzer, Testing Equipment

61-4430-35 SPC Glass Base for Φ90mm 061680-9023

model: 61-4430-35 brand: SIBATA SCIENTIFIC TECHNOLOGY LTD.
2-6391-51 Sterilized Test Bag With Filter (Case Selling)
Analyzer, Testing Equipment

2-6391-51 Sterilized Test Bag With Filter (Case Selling)

model: 2-6391-51 brand: AS ONE Corporation
61-0196-92 Housing Ball Valve PL-1 1/4In. Delrin. NPTM/NPTF 1/Pk 1PK XX1100001
Analyzer, Testing Equipment
61-0192-82 EPDM O-Ring+Plug Seal 5/Pk 5 x 1ST MXPESP5EP
Analyzer, Testing Equipment

61-0192-82 EPDM O-Ring+Plug Seal 5/Pk 5 x 1ST MXPESP5EP

model: 61-0192-82 brand: Merck Millipore Corporation