61-0248-94 Opticap Sterilizing Grade XL2 Aervent 0.2μm 9/16In HB/HB 3/Pk 3 x 1ST KTGRA02HH3
Analyzer, Testing Equipment

61-0248-94 Opticap Sterilizing Grade XL2 Aervent 0.2μm 9/16In HB/HB 3/Pk 3 x 1ST KTGRA02HH3

model: 61-0248-94
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0248-94Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0248-94
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.1
  • Filter bore diameter, μm: 0.2
  • Diameter, cm (inch): 12.5 (4.9)
  • Length, Inch (cm): 5.5 (14.0)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Vent cap material: Polypropylene
  • Material: Hydrophobicity PTFE
  • Housing: Polypropylene
  • Filter brand name: Aervent
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Substitute: KTGP04HB3
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 14mm (9/16in.) hose port
  • Quantity/box: 3
  • Overview: Opticap XL2 Aervent 0.2μm 9/16in. HB/HB
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Hydro-Core test:


    0.12?mL/min @ 260?kPa (38?psig)
  • Bubble point, 23 °C:


    110kPa (16psig) 70/30% IPA/water
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): Normal direction - 552 (80) at 25℃; 103 (15) at 80℃; reverse direction - 414 (60) at 25℃, intermittent
  • Wettability: Hydrophobicity
  • Sterilization: Autoclave sterilization at 135℃ for 30 minutes for 30 times; in-line steam sterilization is unavailable
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 15


    mg after 24


    hours in a 70/30%


    IPA/water mixture at controlled room temperature.
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

63-5226-98 6 ml Transparent Screw Vial, 16 mm, 100 pcs 9301-1377
Analyzer, Testing Equipment
61-0351-66 2-Amino-4,6-Dichlorobenzoic Acid for Synthesis 815106 10G 8.15106.0010
Analyzer, Testing Equipment
62-8377-13 Ezh2/Ezh1 Inhibitor, UNC1999 5.05052.0001
Analyzer, Testing Equipment
62-8436-50 QX-314 552233-100MG
Analyzer, Testing Equipment

62-8436-50 QX-314 552233-100MG

model: 62-8436-50 brand: CBC(Merck)