61-0243-01 Opticap XL5 Polysep II 1/0.2/0.1μm 3/4In. TC/TC 1/Pk 1ST KGW1A05FF1
Analyzer, Testing Equipment

61-0243-01 Opticap XL5 Polysep II 1/0.2/0.1μm 3/4In. TC/TC 1/Pk 1ST KGW1A05FF1

model: 61-0243-01
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0243-01Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0243-01
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 0.17
  • Diameter, cm (inch): 10.7 (4.2)
  • Length, cm (inch): 21.6 (8.5)
  • Length, Inch (cm): 5 (12.5)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Pre-filter material: Borosilicate glass Fiber
  • Vent cap material: Polypropylene
  • Material: Cellulose mixed ester
  • Housing: Polypropylene
  • Format: Triple Layer
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 19mm (3/4in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XL5 Polysep II 1.0/0.2/0.1μm 3/4in. TC/TC
  • Product name: Opticap XL capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • Nominal bore diameter, μm: 1.0 / 0.2 / 0.1
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): 345 (50) @ 25


    °C
  • Sterilization: Autoclave sterilization 3 times for 30 minutes at 121℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 61


    mg per capsule after a 5


    L flush and 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 2L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-0343-03 1,2,3,4-Tetrahydronaphthalene for Synthesis 809733 2.5L 8.09733.2500
Analyzer, Testing Equipment
61-0197-51 Rosolic Acid Dehydrated Bottle 25G 1/Pk 1ST MB000000R
Analyzer, Testing Equipment

61-0197-51 Rosolic Acid Dehydrated Bottle 25G 1/Pk 1ST MB000000R

model: 61-0197-51 brand: Merck Millipore Corporation
62-8504-33 Anti-FOXG1 Antibody, clone 3G11.2 MABD79
Analyzer, Testing Equipment

62-8504-33 Anti-FOXG1 Antibody, clone 3G11.2 MABD79

model: 62-8504-33 brand: Sigma Aldrich Japan(Millipore)
62-8403-41 pET-44c(+) DNA 71124-3
Analyzer, Testing Equipment

62-8403-41 pET-44c(+) DNA 71124-3

model: 62-8403-41 brand: NVG(Merck)