61-0242-99 Opticap XLT30 Polysep II 1/0.2/0.1μm 1.5In. TC/TC 1/Pk 1ST KGW1A3TTT1
Analyzer, Testing Equipment

61-0242-99 Opticap XLT30 Polysep II 1/0.2/0.1μm 1.5In. TC/TC 1/Pk 1ST KGW1A3TTT1

model: 61-0242-99
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0242-99Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0242-99
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 1.26
  • Length from inlet to outlet, cm (inch): 15.2 (6.0)
  • Length, cm (inch): 87.1 (34.3)
  • Length, Inch (cm): 30 (75)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Pre-filter material: Borosilicate glass Fiber
  • Vent cap material: Polypropylene
  • Material: Cellulose mixed ester
  • Housing: Polypropylene
  • Format: Triple Layer
  • Brand name: Opticap
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Capsule
  • Connection, Inlet/outlet: 38mm (1-1/2in.) sanitary flange
  • Quantity/box: 1
  • Overview: Opticap XLT30 Polysep II 1.0/0.2/0.1μm -1-1/2in. TC
  • Product name: Opticap XLT capsule filter
  • Maximum Inlet Pressure (psig): 80
  • Maximum Inlet Temperature, °C: 25
  • T-line/Gauge Port: T-line
  • Nominal bore diameter, μm: 1.0 / 0.2 / 0.1
  • Maximum input pressure, kPa (psi): 552 (80) @ 25


    °C; 276 (40) @ 60


    °C; 103 (15) @ 80


    °C
  • Maximum differential pressure, kPa (psid): 345 (50) @ 25


    °C
  • Sterilization: Autoclave sterilization 3 times for 30 minutes at 121℃; no in-line steam sterilization
  • Sterility: No sterilization
  • Total extract: The extractables level was equal to or less than 435


    mg per capsule after a 15


    L flush and 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 15L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

61-9605-89 GC Capillary Column 12 m×0.22 mm ID -0.1 μm 054631 HT5
Analyzer, Testing Equipment
61-0170-67 Uvette Starter Set 4099 100.007
Analyzer, Testing Equipment

61-0170-67 Uvette Starter Set 4099 100.007

model: 61-0170-67 brand: Eppendorf AG
62-8520-07 Anti-C9ORF72/C9RANT (poly-GA) Antibody, clone 5E9 MABN889
Analyzer, Testing Equipment

62-8520-07 Anti-C9ORF72/C9RANT (poly-GA) Antibody, clone 5E9 MABN889

model: 62-8520-07 brand: Sigma Aldrich Japan(Millipore)
1-352-02 Vacuum Filter Funnel System 2L PLS-8000-1020
Analyzer, Testing Equipment