61-0228-76 Durapore Cart Filt 30In. 1.2+0.5+0.22μm Code 7 3/Pk 3 x 1ST CVSC73TP3
Analyzer, Testing Equipment

61-0228-76 Durapore Cart Filt 30In. 1.2+0.5+0.22μm Code 7 3/Pk 3 x 1ST CVSC73TP3

model: 61-0228-76
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0228-76Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0228-76
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 1.68
  • Filter bore diameter, μm: 1.2 / 0.5 / 0.22
  • Diameter, cm (inch): 6.9 (2.7)
  • Length, Inch (cm): 30 (75)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Pre-filter material: Cellulose mixed ester
  • Material: Hydrophilic PVDF
  • Code: Code 7
  • Filter brand name: Durapore(R)
  • Brand name: Durapore
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Cartridge
  • Quantity/box: 3
  • Overview: Durapore multimedia cartridge filter 30in. 1.2 + 0.5 + 0.22μm code 7
  • Product name: Durapore cartridge filter
  • Air diffusion flow rate, 23 °C:


    32.4mL/min @ 280kPa (40 psig) in water
  • Cartridge code: Code 7 (2-226) with O-ring/locking tab spear
  • Bubble point, 23 °C:


    345kPa (50 psig) air with water
  • Maximum input pressure, kPa (psi): Forward - 5.5 (80) @ 25℃; 1.7 (25) @ 80℃; 0.35 (5) @ 135℃; reverse - 3.5 (50) @ 25℃, intermittent
  • Maximum differential pressure, kPa (psid): Forward - 552 (80) @ 25℃; 172 (25) @ 80℃; 34 (5) @ 135℃; reverse - 345 (50) @ 25℃, intermittent
  • Wettability: Hydrophilic
  • Sterilization: Autoclave sterilization or SIP of 123° for 30 minutes, 6 times
  • Total extract: The extractables level was equal to or less than 70


    mg per 10-inch cartridge after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 15L
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-9976-64 Syringe Vial (Bottle Only) 96 Pieces Included SY-06 202104
Analyzer, Testing Equipment
61-0229-95 Viresolve NFR Cart Filt 10In. Code 7 1/Pk 1ST CZRV71TP1
Analyzer, Testing Equipment

61-0229-95 Viresolve NFR Cart Filt 10In. Code 7 1/Pk 1ST CZRV71TP1

model: 61-0229-95 brand: Merck Millipore Corporation
61-0357-61 Tetra-N-Butylammonium Hydroxide (20% Solution) for Synthesis 818759 100mL 8.18759.0100
Analyzer, Testing Equipment
62-8525-07 Anti-INTS1 Antibody, clone 4.47 MABS1984
Analyzer, Testing Equipment

62-8525-07 Anti-INTS1 Antibody, clone 4.47 MABS1984

model: 62-8525-07 brand: Sigma Aldrich Japan(Millipore)