61-0219-10 Charged Durapore Cart 30In. 0.22μm Code 7 1/Pk 1ST CCGL73TP1
Analyzer, Testing Equipment

61-0219-10 Charged Durapore Cart 30In. 0.22μm Code 7 1/Pk 1ST CCGL73TP1

model: 61-0219-10
brand: Merck Millipore Corporation

Product Description

Product Model: 61-0219-10Product Brand: Merck Millipore […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 61-0219-10
Product Brand: Merck Millipore Corporation

Spec

  • Filtration area, m

    2

    : 2.07
  • Filter bore diameter, μm: 0.22
  • Diameter, cm (inch): 6.9 (2.7)
  • Length, Inch (cm): 30 (75)
  • Support material: Polypropylene
  • Seal material: Silicone
  • Device material: Polypropylene
  • Material: Charged PVDF
  • Code: Code 7
  • Filter brand name: Durapore(R)
  • Brand name: Durapore
  • Main application: Laboratory Filtration
  • Package: Double easy open bag
  • Form: Cartridge
  • Quantity/box: 1
  • Overview: Charged Durapore cartridge 30 in. 0.22μm code 7
  • Product name: Charged Durapore cartridge filter
  • Air diffusion flow rate, 23 °C:


    30mL/min @ 210kPa (30 psig) in water
  • Cartridge code: Code 7 (2-226) with O-ring/locking tab spear
  • Bubble point, 23 °C:


    276


    kPa (40


    psig) wetted with water and air
  • Maximum input pressure, kPa (psi): Forward


    - 5.5 (80) @ 25


    ℃; 1.7 (25) @ 80


    ℃; 0.35 (5) @ 135


    ℃; Backward


    - 3.5 (50) @ 25


  • Maximum differential pressure, kPa (psid): Forward


    - 552 (80) @ 25


    ℃; 172 (25) @ 80


    ℃; 34 (5) @ 135


    ℃; Backward


    - 345 (50) @ 25


  • Flow rate, L/min: 45 @ 1.200


    kPa ΔP
  • Wettability: Hydrophilic
  • Sterilization: SIP of 135℃ for 30 minutes, 10 times
  • Total extract: The extractables level was equal to or less than 20


    mg per 10-inch cartridge after 24


    hours in water at controlled room temperature.
  • Potassium permanganate reduced substance: Will meet the USP Oxidizable Substances Test requirements after a water flush of ? 500mL
  • ※We ask for your kind understanding that lead time might change If it is out of stock in Japan.

Related product recommendations

You may also be interested in the following products

62-8386-44 Anti-a-Insulin Receptor, β subunit; 100 μL 07-724
Analyzer, Testing Equipment

62-8386-44 Anti-a-Insulin Receptor, β subunit; 100 μL 07-724

model: 62-8386-44 brand: Sigma Aldrich Japan(Millipore)
62-8512-31 Anti-CD90.2 (mo***), PE-Cy7, clone 30-H12 MABF728
Analyzer, Testing Equipment

62-8512-31 Anti-CD90.2 (mo***), PE-Cy7, clone 30-H12 MABF728

model: 62-8512-31 brand: Sigma Aldrich Japan(Millipore)
64-1063-71 Reaction decomposition apparatus AB52-2-1
Analyzer, Testing Equipment

64-1063-71 Reaction decomposition apparatus AB52-2-1

model: 64-1063-71 brand: Kiriyama glass Co.
62-8503-32 Anti-TSG101, clone 4A10 Antibody MABC786
Analyzer, Testing Equipment

62-8503-32 Anti-TSG101, clone 4A10 Antibody MABC786

model: 62-8503-32 brand: Sigma Aldrich Japan(Millipore)