![1-3096-02-28 [Discontinued]Thermo-Hygrostat (Temperature Setting: From 10℃) with Pre-shipment Validation LH-114](https://www.jgauge.com/wp-content/uploads/2025/06/4d0a4eca6cdb2a27387f6cd6d56c0585.webp)
laboratoryinstruments
1-3096-02-28 [Discontinued]Thermo-Hygrostat (Temperature Setting: From 10℃) with Pre-shipment Validation LH-114
Product Description
Product Model: 1-3096-02-28Product Brand: ESPEC CORP. F […]
Contact Us
Product Details
Product Model: 1-3096-02-28
Product Brand: ESPEC CORP.
Features
- The PID controlled electronic temperature controller provides excellent temperature control accuracy.
- The automatic temperature rise prevention circuit automatically sets the temperature rise prevention temperature to +10°C higher than the set temperature at the same time as the temperature setting.
- By connecting to the standard Ethernet port (LAN port), you can remotely monitor and control the device from the web screen.
Spec
- Temperature point: 25 deg. C, 50%9 points
- Temperature and humidity setting range: +10°C to +85°C/45~95%RH
- Interior Dimensions (mm): 500 x 390 x 600 (Excluding Protrusion)
- System: Balanced temperature and humidity control system (BTHC system)
- Power Supply: 100 VAC 1φ 50/60Hz
- Temperature and humidity distribution: ±2.0°C/±6%RH
- External Dimensions: 650 x 805 x 1090 mm (Excluding Protrusion)
- Internal Capacity: Approx. 105 L
- Weight: 85 kg
- Maximum current consumption: 15 A
- Power Cord Length: 2m (3P Plug Included)
- Temperature and humidity fluctuation: ±1.0°C/±5%rh
- Temperature and humidity gradient: 5 deg. C/10%rh
- Spatial temperature and humidity deviation: 5°C/10%rh
- *Temperature and humidity control range varies dep***ing on the environmental conditions in which the tester is installed.
- *Transportation, loading, installation and assembly costs are required separately. Please contact us.
- On-site validation services (IQ/OQ) are also available.
- Please contact us.
- *On-site validation service is a service where installation qualification (IQ) and operational performance qualification (OQ) are performed and inspection documents are submitted at the installation site.
- *Do not put flammable materials into the container.
- *If you would like IQOQ on site, please contact us separately. The installation address is required for the quotation.