67-4915-78 Mg3010Series 1 Point Measurement Monitor (Receive: 4~20 Ma, Anoxic Meter Mode I, Display: 0.0~25.0%O2) MG3012-00
toner

67-4915-78 Mg3010Series 1 Point Measurement Monitor (Receive: 4~20 Ma, Anoxic Meter Mode I, Display: 0.0~25.0%O2) MG3012-00

model: 67-4915-78
brand: CHINO CORPORATION
category: toner

Product Description

Product Model: 67-4915-78Product Brand: CHINO CORPORATI […]

Contact Us

Hotline

18866622123

WeChat

WeChat ID: 18866622123

WeChat QR Code

Product Details

Product Model: 67-4915-78
Product Brand: CHINO CORPORATION

Features

  • It receives the output from the oxygen sensor or oxygen meter and gives instructions and alarm.
  • The MG3010 is a dedicated measurement monitor that receives the transmission output signal from the MG1000 series oxygen meter and the MG2100 oxygen sensor at a remote location, and can confirm the measured value and determine the alarm.
  • Equipped with DC voltage output function for MG2100 drive, it can measure and monitor oxygen concentration in the field without power supply.

Spec

  • Receive Signal: 4~20 mA DC (Receive Resistance: 100 Ω or Less)
  • alarm setting
  • Anoxia Meter Mode Type I
  • 18% lower limit, 26% upper limit
  • Buzzer, Lamp, Relay Output With Output Holding
  • Display range: 0.0~25.0%O2
  • Measurement value display: Digital display with 3-digit yellow-green LED
  • Display range (resolution): 0.0~25.0 (0.1)%O2
  • Accuracy rating: ±0.3%O2±1digit
  • DC voltage output
  • Used as a power supply for MG2100
  • Output voltage: 5 V±0.5 V DC
  • Connected Model: 1 MG2100 or MG1000 Series
  • Alarm function: Measured value alarm ...
  • Alarm Setting Code: Anoxic Meter Mode
  • Lower warning value: 18% fixed
  • Upper warning value: fixed at 26%
  • Relay power yes/no: yes
  • Buzzer with/without: Yes
  • Lamp lit/not lit: yes
  • Output holding yes/no: yes
  • Power failure warning: When the power supply to the tester is OFF or when the f*** is broken, relay output is ON.
  • Alarm relay output: number of output circuits (2), output capacity (Resistive Load 110 V AC 0.2 A, 24 V DC 1 A/Inductive Load 110 V AC 0.1 A, 24 V DC 0.5 A)
  • Warm-up time: 5 minutes
  • Note)Alarm signal OFF during warm-up
  • Operating Temperature Range: 0~40°C
  • Operating humidity range: 80%rh or less
  • Power: 100 VAC ±10% 50/60Hz
  • Power Consumption
  • Approx. 5VA for the main body only (when DC voltage output is unloaded)
  • Approx. 8.5VA when ***d in combination with MG2100 series
  • Weight: about 500 g
  • Mounting method: wall or switchbox mounting
  • ISO 14001 Certified JQA-EM2414
  • ISO 9001 Certification JQA-0656