toner
61-9417-92 Gas Detector Tube PYROTEC Tube with Calibration Certificate (With Certificate Of Test) 51H
Product Description
Product Model: 61-9417-92Product Brand: GASTEC Corporat […]
Contact Us
Product Details
Product Model: 61-9417-92
Product Brand: GASTEC Corporation
Features
- * Please let us know the address on the certificate.
Spec
- Detecting tube name: 51H Pyrotube
- Number of measurements of 1 box: 5
- Expiration date (year): 3
- Measurement gas name: Freon11 (trichlorofluoromethane)
- Measurement range: 275 - 6600ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon112 (tetrachlorodifluoroethane)
- Measurement range: 125 - 3000ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon113 (trichlorotrifluoroethane)
- Measurement range: 250 - 6000ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: N0.840
- Measurement gas name: Freon113a (trichlorotrifluoroethane)
- Measurement range: 200 - 4800ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon114 (dichlorotetrafluoroethane)
- Measurement range: 475 - 11400ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon12 (dichlorotetrafluoroethane)
- Measurement range: 325 - 7800ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon22 (chlorodifluoromethane)
- Measurement range: 1000 - 24000ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Halothane
- Measurement range: 800 - 6400ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d, Detection instrument No.840 (9-070-03) only
Related product recommendations
You may also be interested in the following products
65-4289-40 Normal Pressure Gauge (Φ100) Vertical B Frame 0.1 MPa AE20-291
model: 65-4289-40
brand: NAGANO KEIKI Co., Ltd.
61-9412-37 Gas Detector Tube Mercury Vapor with Calibration Certificate (With Certificate Of Test) 40
model: 61-9412-37
brand: GASTEC Corporation
1-1996-21-56 [Discontinued]Waterproof Personal Thermometer (Easy) SN 3200 II Set with English Calibration Certificate
model: 1-1996-21-56
brand: NETSUKEN
1-6732-11-56 Top Plate Balance UP-Y 420g with English Calibration Certificate UP422Y
model: 1-6732-11-56
brand: Shimadzu Corporation