toner
61-9416-76 Gas Detector Tube Acetic Acid with Calibration Certificate (With Certificate Of Test) 81L
Product Description
Product Model: 61-9416-76Product Brand: GASTEC Corporat […]
Contact Us
Product Details
Product Model: 61-9416-76
Product Brand: GASTEC Corporation
Features
- * Please let us know the address on the certificate.
- The concentration of various gases in the air can be easily measured by direct reading.
- You can measure by changing the detector tube with a single detector (pump).
- Beca*** it is directly readable, there is no individual difference and it is accurate.
- Each stroke (100 ml) takes 30 to 240 seconds to complete the intensity measurement.
Spec
- Detecting tube name: 81L acetic acid
- Number of measurements of 1 box: 10
- Expiration date (year): 2 (refrigeration required)
- Measurement gas name: Acrylic Acid (stabilized with MEHQ)
- Measurement range: 0.45 - 18ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Isovaleric Acid
- Measurement range: 0.38 - 15ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Formic acid
- Measurement range: 0.5 - 20ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Propionic Acid
- Measurement range: 0.25 - 10ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Methacrylic Acid (stabilized with MEHQ)
- Measurement range: 0.35 - 14ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Valeric Acid
- Measurement range: 0.38 - 15ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Acetic acid
- Measurement range: 0.125 - 25.0ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: -
- Measurement gas name: Acetic anhydride
- Measurement range: 0.15 - 6ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Butyric Acid
- Measurement range: 0.325 - 13ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
Related product recommendations
You may also be interested in the following products
61-8493-80-20 Ondodori temperature and Humidity Data Logger (wired LAN) with Calibration Certificate TR-72nw
model: 61-8493-80-20
brand: T&D Corporation
65-4322-15-20 Pressure Gauge with Glycerin (100Φ) with 0.4 MPa Inspection Certificate GV42-243
model: 65-4322-15-20
brand: NAGANO KEIKI Co., Ltd.
61-0065-50 Thermometer Miruno TZ White 1514-40
model: 61-0065-50
brand: Sato Keiryoki Mfg. Co., Ltd.
61-9438-58 Anemometer Mini Calibration Report And Calibration Certificate PC-51D
model: 61-9438-58
brand: Sato Keiryoki Mfg. Co., Ltd.