
toner
61-9410-05 Gas Detector Tube 131La Vinyl Chloride with Calibration Certificate (With Certificate Of Test) 131LA
Product Description
Product Model: 61-9410-05Product Brand: GASTEC Corporat […]
Contact Us
Product Details
Product Model: 61-9410-05
Product Brand: GASTEC Corporation
Features
- * Please let us know the address on the certificate.
- The concentration of various gases in the air can be easily measured by direct reading.
- You can measure by changing the detector tube with a single detector (pump).
- Beca*** it is directly readable, there is no individual difference and it is accurate.
- Each stroke (100 ml) takes 30 to 240 seconds to complete the intensity measurement.
Spec
- Detecting tube name: 131La Vinyl chloride
- Number of measurements of 1 box: 5
- Expiration date (year): 2 (refrigeration required)
- Measurement gas name: 1,2,4-Trichlorobenzene
- Measurement range: 0.65 - 13ppm
- Standard suction times (n): 4
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: 1,2-Dichloropropane
- Measurement range: 40 - 800ppm
- Standard suction times (n): 2
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: 1,3-Dichloropropene
- Measurement range: 0.5 - 10ppm
- Standard suction times (n): 2
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: 2-Methylallyl chloride
- Measurement range: 2.8 - 55ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: p-Ethylbenzyl chloride
- Measurement range: 2.5 - 50ppm
- Standard suction times (n): 2
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Ethyl chloroformate
- Measurement range: 7 - 140ppm
- Standard suction times (n): 2
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Methyl chloroformate
- Measurement range: 58 - 1160ppm
- Standard suction times (n): 5
- Measurement time (hr): -
- Special remarks: Conversion factor ***d
- Measurement gas name: Vinyl chloride
- Measurement range: 0.25 - 54ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: -
Related product recommendations
You may also be interested in the following products
61-0115-51 Shock Prevention Rubber Boots (HI8314, HI8424N, Etc.) HI 710015 HI710015
model: 61-0115-51
brand: Hanna Instruments
61-9738-10 Gas Detector Tube 37 Hydrogen (Feeding Method) 11013750
model: 61-9738-10
brand: KITAGAWA, KOMYO RIKAGAKU KOGYO K. K.
65-3530-90 Tape Type Multi-Purpose Temperature Sensor ST Series -50~210°C 2 sec Flat 100 mm K Type ST-21K-010-TS1-ANP
model: 65-3530-90
brand: ANRITSU METER CO., LTD.